Wall mounted type (For KMTB, KMCC, and KMCE)
•
Rotation number range of compressor
Unit: rps
– Model: AOHG14KBTA2
Model name
Outdoor temperature zone
Operating rotation number
ASHG07KMTB
ASHG09KMTB
X zone
28
ASHG12KMTB
ASHG14KMTB
ASHG07KMCC
J zone
28
ASHG09KMCC
ASHG12KMCC
ASHG14KMCC
Y zone
0
ASHG07KMCE
X zone
18
J zone
18
Y zone
0
ASHG09KMCE
ASHG12KMCE
ASHG14KMCE
X zone
14
J zone
14
Y zone
0
– Model: AOHG18KBTA2
Model name
Outdoor temperature zone
Operating rotation number
ASHG07KMTB
ASHG09KMTB
X zone
24
ASHG12KMTB
ASHG14KMTB
ASHG07KMCC
J zone
24
ASHG09KMCC
ASHG12KMCC
ASHG14KMCC
Y zone
0
ASHG07KMCE
X zone
14
J zone
14
Y zone
0
ASHG09KMCE
ASHG12KMCE
ASHG14KMCE
X zone
10
J zone
10
Y zone
0
•
Compressor control based on room temperature
Ts+0.5°C
Ts -1.5
°C
Ts-0.5
°C
Ts+1.5
°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature
1-3. Dry operation
- (04-19) -
1. Rotation number control of compressor
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание AGHG09KVCA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2022 03 15 SR_CH01_MU001EG_04 ...
Страница 40: ...2 6 Outdoor unit 01 34 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 41: ...2 TECHNICAL DATA AND PARTS LIST 2022 03 15 SR_CH02_MU001EG_05 ...
Страница 44: ......
Страница 161: ...3 TROUBLESHOOTING 2022 04 13 SR_CH03_MU001EG_04 ...
Страница 164: ......
Страница 259: ...4 CONTROL AND FUNCTIONS 2022 04 13 SR_CH04_MU001EG_06 ...
Страница 262: ......
Страница 351: ...5 FILED WORKING 2022 04 13 SR_CH05_MU001EG_05 ...