DIP switch setting
•
SW101-Switch 1: Drainage function setting
Switch 1
Drainage function
Factory setting
ON
Disabled
OFF
Enabled
♦
•
SW101-Switch 2: Auto louver grille setting
→hen Auto louver grille kit (optional parts) is attached, set to “Enabled”.
Switch 2
Auto louver grille setting
Factory setting
ON
Enabled
OFF
Disabled
♦
•
SW101-Switch 3: Fan delay setting
→hen the indoor unit is stopped while operating in conjunction with auxiliary heater, the indoor
unit fan operation will continue for 1 minute.
Switch 3
Fan delay
Factory setting
ON
Enabled
OFF
Disabled
♦