6-8. Drain pump control
¢
Drain control for dehumidification operation
During cooling or dry mode
• →hen the compressor starts, the drain pump starts simultaneously.
• The drain pump operates continuously for 3 minutes after the compressor is turned off.
3 minutes
On
Off
On
Off
Compressor
Drain pump
• →hen the compressor stops by the
"Anti-freezing control (cooling and dry mode)"
29, the drain pump is turned off in 1 hour after the compressor stops.
• →hen the float switch is on, the compressor, indoor and outdoor fan motor operation are
stopped.
• Drain pump operates continuously for 3 minutes after the float switch is turned off and then
drain pump is turned off.
• →hen the float switch turns on continuously for 3 minutes, "failure indication" operates. (It is
necessary to turn off power for release it.)
• →hen the float switch turns off less than 3 minutes, the unit starts cooling operation. Indoor
fan motor starts after the float switch is turned off and the compressor starts after 3 minutes st.
3 minutes
3 minutes ST
On
Off
On
Off
On
Off
On
Off
Float switch
Compressor
Indoor fan
Drain pump
Less than 3 minutes
6-8. Drain pump control
- (04-25) -
6. Various control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание ADUH09LUAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AR030EF_01 ...
Страница 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 17: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AR030EF_01 ...
Страница 49: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AR030EF_01 ...
Страница 52: ......
Страница 110: ...5 2 Outdoor unit 03 58 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 111: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AR030EF_01 ...
Страница 145: ...5 FILED WORKING 2021 04 26 SR_CH05_AR030EF_01 ...