3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢
Fan speed
Indoor fan speed is defined as below.
Operation mode
Fan mode
Speed (rpm)
ADUH09LUAS1
ADUH12LUAS1
ADUH18LUAS1
Heating
HIGH
1,260
1,340
1,380
MED
1,160
1,240
1,300
LO→
1,060
1,140
1,220
QUIET
960
1,030
1,140
S-LO→
500
500
600
Cooling/Fan
HIGH
1,260
1,340
1,380
MED
1,160
1,240
1,300
LO→
1,060
1,140
1,220
QUIET
960
1,030
1,140
Soft quiet
500*
1
500*
1
600*
1
S-LO→
500*
2
500*
2
600*
2
Dry
↓ zone: 960
J zone: 960
↓ zone: 1,030
J zone: 1,030
↓ zone: 1,140
J zone: 1,140
*1: Fan mode only
*2: Cooling mode only
¢
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LO→, MED, HIGH while indoor unit fan
only runs.
→hen fan mode is set at AUTO, it operates on MED fan speed.
¢
Cooling operation
Switch the airflow AUTO, and indoor fan motor will run according to room temperature, as below.
On the other hand, if switched in HIGH—QUIET, indoor motor will run at a constant airflow of COOL
operation modes QUIET, LO→, MED, HIGH as shown in “Fan speed” above.
Airflow change over (Cooling: Auto)
When room
temperature rises
When room
temperature drops
Tr - Ts ≥ 4°F (2
°C)
HIGH mode
MED mode
LOW mode
4°F (2
°C)
> Tr - Ts ≥ 2°F (1
°C)
2°F (1
°C) > Tr - Ts
Tr - Ts ≥ 5°F (2.5
°C)
5°F (2.5
°C)
> Tr - Ts ≥ 3°F (1.5
°C)
3°F (1.5
°C) > Tr - Ts
3-1. Indoor fan control
- (04-10) -
3. Fan control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание ADUH09LUAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AR030EF_01 ...
Страница 16: ...2 2 Outdoor unit 01 10 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 17: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AR030EF_01 ...
Страница 49: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AR030EF_01 ...
Страница 52: ......
Страница 110: ...5 2 Outdoor unit 03 58 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Страница 111: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AR030EF_01 ...
Страница 145: ...5 FILED WORKING 2021 04 26 SR_CH05_AR030EF_01 ...