![Fujitsu ABYA12-24LBTH Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/fujitsu/abya12-24lbth/abya12-24lbth_installation-manual_118056005.webp)
En-5
When installing set to wall install the accessory wall bracket at
the position as shown in the
fi
gure, and mount the set to it.
Unit : mm
Wall bracket
Side of set
990
500
65
655
530
45
65
Ø
50
125
100
Ø
100
245
B. Under ceiling type
Using the installation template, drill holes for piping and
suspension bolts (for holes).
Unit : mm
Installation
template
200
Drilling position
for suspension
bolt
Ceiling
Wall
Drilling position for piping
900
B-1. Drilling for piping
Select piping and drain directions.
Top
Rear
(Install the drain hose
in this direction.)
Right
Hole
VIEW
For direction, bore the oval hole shown in the above
fi
gure.
CAUTION
• Install the drain hose at the rear; it should not be installed
on the top or right side.
When the directions are selected, drill 80 mm and 50 mm or
150 mm dia. hole on the wall so that the hole is tilted down-
ward toward the outdoor for smooth water
fl
ow.
Unit : mm
Wall
6
Indoor side
Outdoor side
3.3.1. Preparing indoor unit installation
Open the intake grille and remove the 3 screws.
Machine screw Tapping screw
Tapping screw
Intake grille
Remark : The main unit can be wired before the indoor unit is
installed.
Select the most appropriate installation order.
3.3.2. Indoor unit installation
A. Floor console type
Drilling for piping
Select piping and drain directions.
The piping and drain can be made in 3 directions as shown
below.
VIEW
Hole
For direction, bore the oval hole shown in the above
fi
gure.
The drain hose can be connected to either the left or right
side.
Drain hose
(Right side)
Drain hose
(Left side)
When the directions are selected, drill a 10 cm dia. hole on
the wall so that the hole is tilted downward toward the outdoor
for smooth water
fl
ow.
When the pipe is led out from the rear, make a hole as shown
in the
fi
gure, at the position shown.
Unit : mm
6
100
Wall
Indoor side
Outdoor side
9367701070-05_IM_EN.indd 5
9367701070-05_IM_EN.indd 5
2011-9-16 8:45:00
2011-9-16 8:45:00