En-19
• Refrigerant address example
(Example) ADDRESS : 30
OPERATION
indicator lamp
(Green)
TIMER
indicator lamp
(Orange)
FILTER
indicator lamp
(Red)
9 sec
1 cycle 12 sec
ON
OFF
1.0s
1.0s
1.0s
1.0s
1.0s
1.0s
1.0s
0.5s 0.5s 0.5s 0.5s 0.5s 0.5s
ON
OFF
ON
OFF
OFF
• Setting details
Function
number
Item
Setting number
01
Indoor unit address
00~63
02
Refrigeration address
00~99
For use with a remote controller, set all rotary switches to 0,
and refer to “7.1. Setting the address” for details.
All switches are set to 0 at the factory.
(2) Others
Indication pattern
Indicator Name
Indication pattern
OPERATION
indicator lamp (Green)
Function number; tens place
(0.5s ON/0.5s OFF)
TIMER
indicator lamp (Orange)
Function number; ones place (0.5s
ON/0.5s OFF)
FILTER
indicator lamp (Red)
Setting number: (0 - 9) (0.5s ON/0.5s
OFF)
(Example) Function : 31, Setting number : 2
OPERATION
indicator lamp
(Green)
TIMER
indicator lamp
(Orange)
FILTER
indicator lamp
(Red)
11 sec
10 sec
9 sec
1 cycle 12 sec
ON
OFF
0.5s 0.5s
0.5s
0.5s
0.5s
0.5s
0.5s
0.5s
0.5s
0.5s 0.5s 0.5s
ON
OFF
ON
OFF
8. MOUNT THE COVER PLATE AND
THE INTAKE GRILLE
]1
8.1. Handling for the pipe take-off part
When the pipe is pulled out in the direction shown in the
fi
gure
below, cover the take-off part with material (putty or the like)
that will block it off.
UNDER CEILING TYPE
Top
Right
Rear
FLOOR CONSOLE TYPE
]1
8.2. Mount the cover plate (Right)
(1) Cut a pipe exit hole in the right plate. This is only when
the pipe exits from the right side. (This operation is not
required when the protrusion is on the top or rear.)
Cover plate (Right) (Accessories)
9367701070-05_IM_EN.indd 19
9367701070-05_IM_EN.indd 19