En-13
1
6.4. Connection of wiring
(1) Remove the electric component box.
Electric component box
Electric component box
RFM
CAUTION
• Do not remove the RFM fixing screws. If the stays are
removed, the electric component box will fall.
• If you use as “Floor console”, you must remove screws
and RFMs (2 position).
When removing the electric component box, remove the
clamp from the cables.
After completing the work, fasten the cables as they were
originally by installing the clamp.
Cables
Clamp
Remove the clamp.
Install the clamp.
(2) Pull out the electric component box.
Electric component box
(3) Remove the electric component box cover.
Remove the 3 tapping screws.
Electric component box cover
Base
CAUTION
• Be careful not to pinch the lead cables between the
electric component box and base.
(4) Wiring
* When there is 1 transmission cable or remote controller
cable, fasten it the same way as shown in the
fi
gure with a
binder (medium).
Binder (Medium)
(Accessories)
L, N: Power supply cable
Remote controller cable
Y1: Red, Y2: White, Y3: Black
X1, X2: Transmission cable
]1
6.5. External input and external output
(Optional
parts)
Controller PCB
Input No Voltage terminal (CN17)
Input Voltage terminal (CN6)
Output terminal (CN16)
GND
9367701070-05_IM_EN.indd 13