Timer Operation

Note for timer settings:

Any interruption of the power supply, such as a blackout or cutting off of a circuit breaker, makes the set internal clock incorrect.

In such a case, the TIMER indicator on the indoor unit blinks, and you need to readjust the setting.

ON timer or OFF timer

1

  Turn on the indoor unit by pressing the START/STOP button.

OPERATION indicator on the indoor unit turns on.

If the indoor unit is already operating, skip this step.

2

  Press the ON timer button or the OFF timer button.

Clock indicator on the remote controller display starts blinking, 

and TIMER indicator on the indoor unit turns on.

3

  Adjust the time by pressing the SELECT button within about 5 

seconds, while the clock indicator is blinking.

(About 5 seconds later, the remote controller display returns to 

standby screen.)

To cancel the timer and return to normal operation, press the CANCEL 

button.

To redo the timer setting, perform step 2 and 3.

Program timer (combined use of the ON timer and the OFF timer)

You can set an integrated ON–OFF or OFF–ON timer.

Either of the timer whose configured starting time is closer to the 

current time works first, and the order of timer operation is displayed 

as follows:

Timer

Indicator on remote controller display

ON–OFF timer

OFF–ON timer

The timer that is set later starts counting down after the counting 

down of the preceding timer is finished.

To set the program timer, conduct the same steps 2~3 for the ON/

OFF timer.

Notes:

• If you change the setting value for the timer after the program timer 

is set, the counting down of the timer will be reset at that moment.

• Time setting for each combination should be within a span of 24 hours.

SLEEP timer

1

  Press the SLEEP timer button to activate the SLEEP timer.

OPERATION indicator and TIMER indicator on the indoor unit turns on.

2

  Adjust the time by pressing the SELECT button within about 5 

seconds, while the clock indicator is blinking.
(About 5 seconds later, the remote controller display returns to 

standby screen.)
Each time you press the button, the time changes as follows:

9.0

7.0

5.0

3.0

2.0

1.0

0.5

hours

(30 min.)

To repeat the timer, press the SLEEP timer button when 

 

indicator is not displayed on the remote controller display.

To help you to fall asleep comfortably and prevent excessive warming 

or cooling in sleep, the SLEEP timer controls the temperature setting 

automatically in accordance with the set time shown as follows. The 

air conditioner completely turns off after the set time has elapsed.

In HEAT mode

Set 

temperature

Set time

1 hour

Set time

1 hour

1.5 hour

30 min.

1 °C 2 °C 3 °C 4 °C

2 °C

1 °C

In COOL or DRY mode

90°

7 m

7 m

50°

50°

●  Application range is follows.

Vertical angle 90° (Side view)

Horizontal angle 100° (Top view)

ENERGY SAVING function may not work when the room temperature is 

very different from the temperature defined in temperature setting, such 

as when immediately after starting the operation.

About the HUMAN SENSOR

 

Details about detection with the human sensor

 

 The human sensor detects whether there are people in the room 

by looking for movement by people in the room.

 

Since the human sensor detects infrared light given out by 

people, there may be cases where this detection is incorrect.

Situations in which the sensor will detect no people in the 

room, even when there is someone there

 

 When the temperature is high and the difference with 

between people’s body temperature is small.

(Such as during the summer when the temperature is 30˚C 

or higher)

 

 When there is someone in the room, but they do not move 

for a long period of time.

 

 When someone is hidden behind a sofa, other furniture, 

glass, or in similar situations.

 

 When someone is wearing extremely thick clothing and has 

their back facing the sensor.

Situations in which the sensor will incorrectly detect people 

in the room, even when there is no one there

 

 When there is a dog or a cat moving around in the room.

 

 When the wind is making curtains or plants move.

 

 When there are heating units, humidifiers, or electric 

appliances such as oscillating electric fans operating.

Notice

To prevent waste of electricity, this function controls the temperature 

setting when no one is occupying the room. Energy Saving program is 

on at the time of purchase.

1

  To activate the Energy Saving program, press the SENSOR 

button.

 indicator will be flashing on the remote controller 

display.

2

  To deactivate the Energy Saving program, press the SENSOR 

button again.

 will no longer be shown on the remote controller 

display.

About the ENERGY SAVING Operation

If no one enters the room for approximately 20 minutes, the set 

temperature will be automatically controlled. 

(When someone comes back into the room, the human sensor will 

detect this, and automatically revert to the original settings.)

Operation 

mode

Operating details 

(if there is no one in the room for a while)

COOL/DRY The set temperature will be increased by a maximum of 

approximately 2˚C.

HEAT

The set temperature will be decreased by a maximum 

of approximately 4˚C.

AUTO

This runs the ENERGY SAVING function automatically 

for the selected mode (Cooling/ Heating/ Drying).

● When using together with the SLEEP timer (page 5), the SLEEP 

timer will be prioritized.

● During 10°C HEAT operation, if there is no one in the room the set 

temperature will not be changed.

Human Sensor (Energy Saving)

9333003030-02_OM_EN.indd   5

10/6/2014   11:01:45 AM

Содержание 9333003030-02

Страница 1: ...he cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate the unit with air filters installed Ensure that any electronic equipment is at least 1 meter away from either the indoor unit or outdoor unit Unplug the power supply cable when n...

Страница 2: ... of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiver CAUTION For appropriate signal transmission between remote controller and indoor unit keep the signal receiver away from the following items ...

Страница 3: ... range noticeably got shorten replace the batteries and press RESET button You can quickly start operation with the following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for about 3 5 minutes fo...

Страница 4: ...peed or is stopped In FAN mode swing operation range of 1 3 or 4 7 is decided according to the airflow direction previously set before starting the swing operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airflow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control 12 Time...

Страница 5: ...et time 1 hour 1 5 hour 30 min 1 C 2 C 3 C 4 C 2 C 1 C In COOL or DRY mode 90 7 m 7 m 50 50 Application range is follows Vertical angle 90 Side view Horizontal angle 100 Top view ENERGY SAVING function may not work when the room temperature is very different from the temperature defined in temperature setting such as when immediately after starting the operation About the HUMAN SENSOR Details abou...

Страница 6: ...see the Operation manual for the wired remote controller When the restricted functions on the wireless remote controller are selected beeping sound will be heard OPERATION TIMER and the 3rd lamp of the indoor unit will flash Restricted functions for wireless remote controller ENERGY SAVING PROGRAM OUTDOOR UNIT LOW NOISE OPERATION ON OFF TIMER PROGRAM TIMER SLEEP TIMER POWERFUL OPERATION Multi type...

Страница 7: ... the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating...

Страница 8: ...ry the filter throughly in shaded place 6 Reinstall the filter to the indoor unit Replace the filter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulate...

Страница 9: ...matic defrosting operation while the OPERATION indicator is flashing 6 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring operation...

Отзывы: