En-2

OPERATING MANUAL

Indoor Unit Overview and Operations

1  Intake grille

Before starting operation, make sure that the intake grille has been 

shut completely. Incomplete closing may have an effect on the proper 

function or performance of the product.

2  MANUAL AUTO button

Use when the remote controller is lost or there is a malfunction.

Status

Action

Mode or operation

In operation

Press more than 3 seconds.

Stop

Stopping

Press more than 3 seconds and 

less than 10 seconds.

AUTO

Press more than 10 seconds.

(Only for servicing.*)

Forced cooling

After cleaning

Press less than 3 seconds.

Filter indicator reset

*:To stop forced cooling, press this button or START/STOP button on 

the remote controller.

3  Front panel

See page 5

4  Human Sensor

Used for Energy Saving Program. Controls temperature setting by 

detecting people in the room.

5  Vertical airflow direction louver

Each time you press SET button on the remote controller, the angle 

of the vertical airflow direction louver moves as follows:

1

2

3

4

5 6

7

COOL or DRY mode

HEAT mode

1

2

3

7

6

5

*

*

4

*: Default setting in each mode.

• Do not adjust by hand.

• At the beginning of AUTO or HEAT mode, they may stay on position 

1 for a while for adjustment.

• If the angle is set to position 4–7 for more than 30 minutes in COOL 

or DRY mode, the louver will automatically return to position 3.

• Keeping the position 4-7 during COOL or DRY mode may cause 

condensation to form, and the drops may damage your property.

6  Power diffuser

In conjunction with movement of the vertical airflow direction louver, 

the angle of the power diffuser moves as follows:

Vertical airflow 

direction louver

Power diffuser

3

7

6

5

4

2

1

3

2

1

4

• In SWING operation, power diffuser does not move.

7  Drain hose

8  Remote controller signal receiver

 

CAUTION

For appropriate signal transmission between remote controller and 

indoor unit, keep the signal receiver away from the following items:

 -Direct sunlight or other strong lights

 -Flat-panel television screen

In rooms with instantaneous fluorescent lights, such as 

inverter type ones, the signal may not be transmitted properly. 

In such a case, consult the store of purchase.

9  ECONOMY indicator (green)

Lights in ECONOMY operation and in 10 °C HEAT operation.

10  TIMER indicator (orange)

Lights in TIMER operation, and blinks slowly when the timer setting 

error is detected.

For details, refer to “Auto-restart function” on page 6.

7

1

3

4

5

6

9

10

11

12

14

2

13

8

11  OPERATION indicator (green)

Lights in normal operation, and blinks slowly in Automatic defrosting 

operation.

12  Horizontal airflow direction louvers

 

CAUTION

Before you adjust the horizontal airflow direction, make sure that 

the vertical airflow direction louver has been stopped completely.

Adjust two knobs by hand.

See page 7

13  Air filter

See page 8

14  Air cleaning filters

Purify or deodorize the air, and provide fresh airflow.

Indoor unit accessories

Remote 

controller

Air cleaning filters

Filter holders

Remote controller 

holder

Tapping screws

(M3 × 12 mm)

 

WARNING

Take care to prevent infants and young children from acciden-

tally swallowing the batteries.

Remote controller holder installation

3

2

1

Screws

Insert

Slide up

9333003030-02_OM_EN.indd   2

10/6/2014   11:01:43 AM

Содержание 9333003030-02

Страница 1: ...he cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate the unit with air filters installed Ensure that any electronic equipment is at least 1 meter away from either the indoor unit or outdoor unit Unplug the power supply cable when n...

Страница 2: ... of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiver CAUTION For appropriate signal transmission between remote controller and indoor unit keep the signal receiver away from the following items ...

Страница 3: ... range noticeably got shorten replace the batteries and press RESET button You can quickly start operation with the following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for about 3 5 minutes fo...

Страница 4: ...peed or is stopped In FAN mode swing operation range of 1 3 or 4 7 is decided according to the airflow direction previously set before starting the swing operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airflow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control 12 Time...

Страница 5: ...et time 1 hour 1 5 hour 30 min 1 C 2 C 3 C 4 C 2 C 1 C In COOL or DRY mode 90 7 m 7 m 50 50 Application range is follows Vertical angle 90 Side view Horizontal angle 100 Top view ENERGY SAVING function may not work when the room temperature is very different from the temperature defined in temperature setting such as when immediately after starting the operation About the HUMAN SENSOR Details abou...

Страница 6: ...see the Operation manual for the wired remote controller When the restricted functions on the wireless remote controller are selected beeping sound will be heard OPERATION TIMER and the 3rd lamp of the indoor unit will flash Restricted functions for wireless remote controller ENERGY SAVING PROGRAM OUTDOOR UNIT LOW NOISE OPERATION ON OFF TIMER PROGRAM TIMER SLEEP TIMER POWERFUL OPERATION Multi type...

Страница 7: ... the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating...

Страница 8: ...ry the filter throughly in shaded place 6 Reinstall the filter to the indoor unit Replace the filter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulate...

Страница 9: ...matic defrosting operation while the OPERATION indicator is flashing 6 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring operation...

Отзывы: