4  Remote controller display

In this section, all the possible indicators are displayed for description. 

In actual operation, the display is linked with the button operation, and 

only shows the necessary indicators for each setting.

5  POWERFUL button

Activates the POWERFUL operation.
The unit will operate at maximum power and strong airflow to quickly 

cool down or warm up the room.
When activated, the indoor unit will emit 3 short beeps. 
POWERFUL operation is automatically turned off in the following 

situations:

• Adjusted room temperature reaches the set temperature in COOL, 

DRY, or HEAT mode.

• 20 minutes have passed after the POWERFUL operation mode has 

been set.

Even in situations above, the POWERFUL operation will not 

automatically turn off unless it has run for a certain amount of time.

Notes:

• The airflow direction and the fan speed are controlled automatically.

• This operation cannot be performed simultaneously with ECONOMY 

operation.

To return to normal operation, press the button again. Then the indoor 

unit will emit 2 short beeps.

6  10 

°

C HEAT button

Starts 10 °C HEAT operation that maintains the room temperature at 

10 °C so as to prevent the room temperature to drop too low.

After pressing the button to start the 10 °C HEAT operation, the 

indoor unit emits 2 short beeps and the ECONOMY indicator (green) 

will turn on.

Notes:

• In 10 °C HEAT operation mode, only vertical airflow direction can be 

adjusted by using 

 button.

• HEAT mode will not be performed if the room temperature is warm enough.

• In multi-type air conditioning system, if other indoor unit is in HEAT 

mode, the temperature of the room where 10 °C HEAT operation is 

performed will rise. When performing 10 °C HEAT operation, all the 

indoor units should be run in 10 °C HEAT operation mode.

To turn off, press the START/STOP button.

The ECONOMY indicator will turn off.

7  Signal transmitter

Aim to signal receiver of the indoor unit properly.

• Signal transmit indicator   on the remote controller display shows 

that signal from the remote controller is being transmitted.

• Operating range is approximately 7 m.

• You will hear a beep if the transmitted signal has been sent properly.  

If there is no beep, press the button on the remote controller again.

8  FAN button

Controls the fan speed.

(AUTO)

(HIGH)

(MED)

(LOW)

(QUIET)

• When AUTO is selected, the fan speed is automatically adjusted 

according to the operation mode.

9  SWING button

Starts or stops automatic swing of the vertical airflow direction louver.

• Each time you press the button, the vertical airflow direction louver 

swings as follows:

COOL, DRY, or FAN 

mode

HEAT or FAN mode

1

2

3

3

7

6

5

4

1

2

3

3

7

6

5

4

1

2

3

4

5 6

7

Notes:

• SWING operation may stop temporarily when the indoor unit fan is 

rotating at very low speed or is stopped.

• In FAN mode, swing operation range of 1 

 3 or 4 

 7 is decided 

according to the airflow direction previously set before starting the 

swing operation.

Remote Controller Overview and Operations

10  SET button

Adjusts the vertical airflow direction.

See page 5

11  SLEEP timer button

Activates the SLEEP timer that helps you to fall asleep comfortably 

with gradual temperature control.

12  Timer CANCEL button

Cancels the set timer.

13  RESET button

When you press the RESET button, press it gently by using the tip of a 

ballpoint pen or other small object in correct direction as shown in this figure.

See page 3

14  CLOCK ADJUST button

Used for adjusting the clock.

See page 3

15  OFF timer button

Activates the OFF timer.

See page 5

16  ON timer button

Activates the ON timer.

17  SELECT button

Used for adjusting the clock or timer.

See page 3

18  OUTDOOR UNIT LOW NOISE button

Starts or stops OUTDOOR UNIT LOW NOISE operation that lowers 

noise generated from the outdoor unit by cutting down the rotation 

number of the compressor, and suppressing the fan speed.

Once the operation is set, the setting is preserved until you press this button 

again to stop the operation, even if the indoor unit operation is stopped.

 on the remote controller display shows that the unit is in 

OUTDOOR UNIT LOW NOISE mode.

Notes:

• This operation cannot be performed simultaneously with FAN, DRY 

and POWERFUL operation modes.

• This operation cannot be performed on a multi-type air conditioner.

If this mode is unintentionally set on a multi-type air conditioner, 

cancel the setting by pressing the button. Otherwise, the signal of 

the remote controller cannot be transmitted properly.

19  ECONOMY button

Starts or stops ECONOMY operation that saves more electricity 

than other operation modes by changing the set temperature to a 

moderate setting.

By pressing the ECONOMY button, the ECONOMY indicator on the 

indoor unit turns on.

• In COOL or DRY mode, the room temperature will be adjusted a few 

degrees higher than the set temperature.

• In HEAT mode, the room temperature will be adjusted a few 

degrees lower than the set temperature.

• Especially in COOL or DRY mode, you can have improved 

dehumidification without significantly lowering the room temperature.

Notes:

• In COOL, HEAT, or DRY mode, the maximum output of this 

operation is approximately 70 % of usual air conditioning operation.

• This operation cannot be performed during temperature monitoring 

by AUTO mode.

• In multi-type air conditioning system, ECONOMY operation is 

performed only on the indoor unit whose ECONOMY button on the 

corresponding remote controller is pressed.

See page 8

20  SENSOR button (ENERGY SAVING)

Activates or deactivates the energy saving. 

* The Energy Saving is ON at the time of purchase.

:   The setting must be done while the setting screen is displayed for 

each function.

 :  The button is controllable only when the air conditioner is on.

RESET

9333003030-02_OM_EN.indd   4

10/6/2014   11:01:45 AM

Содержание 9333003030-02

Страница 1: ...he cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate the unit with air filters installed Ensure that any electronic equipment is at least 1 meter away from either the indoor unit or outdoor unit Unplug the power supply cable when n...

Страница 2: ... of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 7 Drain hose 8 Remote controller signal receiver CAUTION For appropriate signal transmission between remote controller and indoor unit keep the signal receiver away from the following items ...

Страница 3: ... range noticeably got shorten replace the batteries and press RESET button You can quickly start operation with the following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for about 3 5 minutes fo...

Страница 4: ...peed or is stopped In FAN mode swing operation range of 1 3 or 4 7 is decided according to the airflow direction previously set before starting the swing operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airflow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asleep comfortably with gradual temperature control 12 Time...

Страница 5: ...et time 1 hour 1 5 hour 30 min 1 C 2 C 3 C 4 C 2 C 1 C In COOL or DRY mode 90 7 m 7 m 50 50 Application range is follows Vertical angle 90 Side view Horizontal angle 100 Top view ENERGY SAVING function may not work when the room temperature is very different from the temperature defined in temperature setting such as when immediately after starting the operation About the HUMAN SENSOR Details abou...

Страница 6: ...see the Operation manual for the wired remote controller When the restricted functions on the wireless remote controller are selected beeping sound will be heard OPERATION TIMER and the 3rd lamp of the indoor unit will flash Restricted functions for wireless remote controller ENERGY SAVING PROGRAM OUTDOOR UNIT LOW NOISE OPERATION ON OFF TIMER PROGRAM TIMER SLEEP TIMER POWERFUL OPERATION Multi type...

Страница 7: ... the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating...

Страница 8: ...ry the filter throughly in shaded place 6 Reinstall the filter to the indoor unit Replace the filter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulate...

Страница 9: ...matic defrosting operation while the OPERATION indicator is flashing 6 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring operation...

Отзывы: