MB95630H Series
MN702-00009-2v0-E
FUJITSU SEMICONDUCTOR LIMITED
237
CHAPTER 14 LIN-UART
14.6 Operations of LIN-UART and LIN-UART
Setting Procedure Example
14.6.6
Master/Slave Mode Communication Function
(Multiprocessor Mode)
Operating mode 1 allows communication among multiple CPUs connected in
master/slave mode. The LIN-UART can be used as a master or a slave.
■
Master/Slave Mode Communication Function
To operate the LIN-UART in multiprocessor mode (operating mode 1), the settings shown in
Figure 14.6-13 are required.
Figure 14.6-13 Settings of LIN-UART Operating Mode 1
●
Inter-CPU connection
For master/slave mode communication, a communication system consists of two common
communication lines connecting between one master CPU and multiple slave CPUs as shown
in Figure 14.6-14. The LIN-UART can be used as a master or a slave.
Figure 14.6-14 Connection Example of LIN-UART Master/Slave Mode Communication
●
Function selection
In master/slave mode communication, select the operating mode and the data transfer method
as shown in Figure 14.6-14.
bit15 bit14 bit13 bit12 bit11 bit10 bit9
bit8
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
SCR, SMR
PEN
P
SBL
CL
AD
CRE RXE TXE MD1 MD0 OTO EXT REST UPCL SCKE SOE
Mode 1
→
+
×
0
0
1
0
0
0
SSR,
RDR/TDR
PE
ORE FRE RDRF TDRE BDS RIE
TIE
Set compare data (during writing)
Retain receive data (during reading)
Mode 1
→
×
ESCR, ECCR LBIE LBD LBL1 LBL0 SOPE SIOP CCO SCES
Reserved
LBR
MS SCDE SSM
Reserved
RBI
TBI
Mode 1
→
×
×
×
×
0
0
0
×
×
×
×
0
: Bit to be used
× : Unused bit
1 : Set to "1"
0 : Set to "0"
+ : Bit correctly set automatically
SOT
SIN
SOT
SIN
SOT
SIN
Master CPU
Slave CPU #0
Slave CPU #1
Содержание 8FX
Страница 2: ......
Страница 4: ......
Страница 8: ...iv ...
Страница 17: ...xiii A 3 Bit Manipulation Instructions SETB CLRB 621 A 4 F2 MC 8FX Instructions 622 A 5 Instruction Map 625 ...
Страница 18: ...xiv ...
Страница 22: ...xviii ...
Страница 108: ...MB95630H Series 86 FUJITSU SEMICONDUCTOR LIMITED MN702 00009 2v0 E CHAPTER 6 I O PORT 6 2 Configuration and Operations ...
Страница 284: ...MB95630H Series 262 FUJITSU SEMICONDUCTOR LIMITED MN702 00009 2v0 E CHAPTER 14 LIN UART 14 8 Notes on Using LIN UART ...
Страница 648: ...MB95630H Series 626 FUJITSU SEMICONDUCTOR LIMITED MN702 00009 2v0 E APPENDIX A Instruction Overview A 5 Instruction Map ...
Страница 650: ......