A26361-K554-Z100-2-7619
39
Technical data
Electrical data
Regulations complied with:
EN 60950 / VDE 0805, UL 1950
CSA 22.2 No.950
Protection class:
I
Rated voltage range: (selectable)
100 V -120 V / 200 V - 240 V
Frequency:
50 Hz - 60 Hz
Max. rated current
100 V -120 V/2.5 A
200 V -240 V/1.5 A
Maximum power draw in operation:
< 50 W *)
Minimum power draw in operation:
reduced by Windows 9x
Power
management advanced
< 30 W *)
Power draw in energy saving mode:
< 30 W *)
Power draw in the 'ready' status
< 5 W *)
Noise emission:
Sound power level (L
WAd
) < 55 dB (A) *)
*)
These values only apply for a SCENIC eT with the configuration below. When additional or
other components are incorporated, the power consumption or the sound emission (L
WAd
) in
energy saving mode may exceed the requirements for the environment symbol ("Blue Angel")
(30 W or 55 dB).
Processor (256 Kbyte cache):
Pentium III Processor at 933 MHz
Main memory:
128 Mbyte
Floppy disk drive:
1.44 Mbyte
Hard disk drive:
20 Gbyte
Software:
Windows 98 SE
Power management - Advanced...
CD-ROM drive
48fold
LAN:
10/100 Mbit Ethernet Controller
Dimensions
Width/depth/height:
196 mm/350 mm/ 360 mm
Weight
in basic configuration
ca. 8 kg (78.5 N) in basic configuration
Environmental conditions
Environment class 3K2
Environment class 2K2
DIN IEC 721 part 3-3
DIN IEC 721 part 3-2
Temperature:
•
Operating (3K2)
•
Transport (2K2)
15 °C .... 35 °C
-25 °C .... 60 °C
Condensation in operating must be avoided.
Clearance required to ensure adequate ventilation:
•
left-hand side
•
front
•
rear
min. 200 mm
min. 200 mm
min. 200 mm