Fujitec MO-1330 Скачать руководство пользователя страница 8

5.Maintenance

Before starting cleaning, be sure to turn OFF power switch on
controller.
If the unit is to be disused for an Extended period, keep power
cord unplugged.

■Daily maintenance

Clean off dust and dirt form the unit with new cloth.
If dirt is very heavy, clean it off with cloth moistened by 
industrial alcohol.

■Monthly maintenance

(Frequency varies depending on operation conditions.)

Brush inspection and replacement

Inspect bursh periodically since brush wears out as its
rotation time accumulates and replace it with new one
as necessity requires.
※Do not use worn brush since this may affect motor
performance and service life.

① Remove brush cap using minus thread driver.

② Wear gloves free from oil and water and pull brush out

with hand.
※Touching brush with bare hands results in defective

insulation.

※Be sure to remember proper orientation ( top/bottom) of

brush and holder position to return it to original position.
( To protect rectifier )

③ Replace brush before its length becomes 5mm ro less.

カーボンブラシ

 

Carbon  brush 

Brush 

Brush  cap 

Minus   driver 

-7-

Содержание MO-1330

Страница 1: ...INSTRUCTION MANUAL Electric Screwdriver MO 1330 MO 1350 Controller DO 1390A CO 1390A 2 FUDOC 110630 ...

Страница 2: ... DO 1390A 2 P3 2 Precautions for Use P4 3 Preparation P4 How to install P4 How to connect P4 4 Operation P5 Inspection before operation start check if that P5 Trial operation P5 Operation P5 Stop P5 5 Maintenance P6 Daily maintenance P6 Monthly maintenance P6 Adjustment P7 Consumable parts replacement P7 6 Motion Timing Chart P8 7 Troubleshooting P8 8 Specifications P9 9 DO 1390A 1 Phase 2 Phase T...

Страница 3: ...er side metal outlet 2P PLT 162 R panel side PLT 162 P Brush cap Fixes and protects brush If turned clockwise brush cap tightens if turned counterclockwise it loosens Holder Please tighten one page driver s center of the gripper with 5 8 N m Output shaft Transmits screwdriver rotationn to bit CONNECTOR FOR DRIVER CONNECTOR OSU 1545P PIN OSU 1380TL Terminal Spanner opposete 32mm Brush Cap Output sh...

Страница 4: ... to screwdriver Panel side PLT 162 R Harness side PLT 162 P Fuse holder 3A Used to protect and replace fuse Metal outlet 5P Connecter to input output signals Panel side PLT 165 R Harness side PLT 165 P Power cord Plugged into AC100V power source Adjustment at motor lock time Can it tighten and the following maintenance officer be adjusted Adjustment at motor lock Metal outlet Fuse holder Power Met...

Страница 5: ...ched Metal outlet 2P Connected to input output signals Panel side PLT 162 R Harness side PLT 162 P Fuse holder 3A Used to protect and replace fuse Metal outlet 5P Connected to input output signals Panel side PLT 165 R Harness side PLT 165 P Power cord Plugged into AC100V power source Adjustment at motor lock time Can it tighten and the following maintenance officer be adjusted Adjustment at motor ...

Страница 6: ...ntroller is OFF Plug power cord on the back of controller into AC100V power supply outlet Plug screwdriver cord into metal outlet 2P on the back of controller Caution Be sure to use exclusive controller DO 1390A DO 1390A 2 2P metal outlet For MO 1330 1350 Connect input signal start signal to input output terminal metal outlet 5P on the back of controller Input signal must be no voltage contact sig...

Страница 7: ...for trouble If any trouble should be found be sure to repair as soon as possible Operation Set screwdriver select switch in the front of controller in accordance with model No of electric screwdriver used MO 1330 133 MO 1350 135 DO 1390A DO 1390A 2 Caution If screwdriver s model No does not coincide with the selected No on the swich screwdriver may not work or motor may be burned Set torque knob o...

Страница 8: ...Inspect bursh periodically since brush wears out as its rotation time accumulates and replace it with new one as necessity requires Do not use worn brush since this may affect motor performance and service life Remove brush cap using minus thread driver Wear gloves free from oil and water and pull brush out with hand Touching brush with bare hands results in defective insulation Be sure to remembe...

Страница 9: ... torque applied to actual fastening Regard it as static torque and make a distinction between static torque and dynamic torque For related information page 12 14 Ajustment of motor lock time After fastening screw with a determined torque keep motor torque at the same level for certain time lock time Adjust lock time by inserting minus thread screwdriver into adjust bolt hole on the top face of con...

Страница 10: ...oes not rotate Motor does not rotate smoothly Motor does not stop automatically when fastening is complate Power cord is unplugged Fuse is blown or is not insert Screwdriver model No does not coincide with screwdriver select No Screwdriver cord is not connected to screwdriver output terminal Cable inside disconnection Carbon brush wear Carbon brush wear Check wiring Replace fuse or install fuse Se...

Страница 11: ... 60 or less in case of room temperature of 20 taking heat emission of motor into consideration Note Overcurrent indicator lamp OCP When an overcurrent lamp turned on by the trouble of the motor the disconnection of the driver cable off does a main switch and can continue it if I do ON 3 sec later 750 M1 4 M2 5 2 3 M3 M4 2 5 4 3 4 M3 M5 Rated output DC23 76V 195 including output shaft 0 40 Ambient ...

Страница 12: ... DO 1390A 2 Contorol Box 1 2 T1 T2 T1 3 Patterns of fastening T2 T1 T2 No Reduce inertial energy of motor to fastening torque Needs fastening tact T1 T2 t Timer T1 T2 Strong start fatening torque and weak final fastening torque Reduce fastening tact T1 T2 Machine screws Aptitudes and Notes of fastening Strong start fastening torque and weak final tastening torque Needs height detection and timer w...

Страница 13: ...repair service check the unit again in accordance with Torubleshooting on page 8 If the trouble can not be solved with measures given on page 8 please consult with your dealer After sales service If you have any questions please make inquiries to your dealer Please inquire an uncertain point of the shop 5P Metal Outlet 1 5 3P Nylon Connector 5P Metal Outlet 2 3 5P Mtal Outlet 2 4 Start signal Scre...

Страница 14: ...nt is proportionate to fastening torque since DC motor is used Not to stop motor with starting current the follwing condition is adopted t1 t2 Current detection level for I 1 is set to 75 of I 0 I0 Motor starting current I1 Detected current 0 75 10 t1 Current delay time in I1 50ms as follows t2 Delay time t2 t1 t2 t3 Holding time 0 05 Constant voltage regulated power supply circuit torque changeab...

Страница 15: ... inertial energy of motor rotor Type How to measure Torque waverorm static Torque TS Torque inverter Electric screwdriver Input Connector Ampli fier Electro magnetic oscillo scope Record Tp Max torque Ts Static torque Type How to measure Torque waverorm TD Torque Torque Checker Actual screw fastening Electric screwdrive Torque Input Input Peak indicator Electric screw driver Electro magnetic oscil...

Страница 16: ... Relation between theoretical value static torque and actual fastening torque dynamic torque Ex MO 1330B 0 48 2 33 0 2 5 2 0 1 5 1 0 0 5 2 4 6 8 10 トルク目盛 Torque checker Static torque Iron board Machine Plasti c Torque N m Theoretical value for MO 1330B Static torque See page 9 Machine screw Torque dynamic torque added by inertial energy of motor rotor Increased by 10 50 of theoretical value NOTE S...

Страница 17: ...Item No Dated purchased 年 月 日 Dealer TEL FUJITEC CO LTD 1 10 6 Ryoke Nakaku Hmamamatsu city Shizuoka ken 430 0852 JAPAN TEL 053 462 3636 FAX 053 462 1818 Ver 04 100414 ...

Отзывы: