![FujiFilm FVR-Micro Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/fujifilm/fvr-micro/fvr-micro_instruction-manual_2343270079.webp)
Terminal function assignment and data setting
Select multistep frequency (0 to 15 steps) --
SS1
,
SS2
,
SS4
, and
SS8
(Function code data = 0, 1, 2, and 3)
The combination of the ON/OFF states of digital input signals
SS1
,
SS2
,
SS4
and
SS8
selects one of
16 different frequency commands defined beforehand by 15 function codes C05 to C19 (Multistep
frequency 0 to 15). With this, the inverter can drive the motor at 16 different preset frequencies.
The table below lists the frequencies that can be obtained by the combination of switching
SS1
,
SS2
,
SS4
and
SS8
. In the "Selected frequency" column, "Other than multistep frequency"
represents the reference frequency sourced by frequency command 1 (F01), frequency command
2 (C30), or others.
SS8
SS4
SS2
SS1
Selected frequency
OFF
OFF
OFF
OFF
Other than multistep frequency
OFF
OFF
OFF
ON
C05 (Multistep frequency 1)
OFF
OFF
ON
OFF
C06 (Multistep frequency 2)
OFF
OFF
ON
ON
C07 (Multistep frequency 3)
OFF
ON
OFF
OFF
C08 (Multistep frequency 4)
OFF
ON
OFF
ON
C09 (Multistep frequency 5)
OFF
ON
ON
OFF
C10 (Multistep frequency 6)
OFF
ON
ON
ON
C11 (Multistep frequency 7)
ON
OFF
OFF
OFF
C12 (Multistep frequency 8)
ON
OFF
OFF
ON
C13 (Multistep frequency 9)
ON
OFF
ON
OFF
C14 (Multistep frequency 10)
ON
OFF
ON
ON
C15 (Multistep frequency 11)
ON
ON
OFF
OFF
C16 (Multistep frequency 12)
ON
ON
OFF
ON
C17 (Multistep frequency 13)
ON
ON
ON
OFF
C18 (Multistep frequency 14)
ON
ON
ON
ON
C19 (Multistep frequency 15)
Select ACC/DEC time --
RT1
(Function code data = 4)
This terminal command switches between ACC/DEC time 1 (F07, F08) and ACC/DEC time 2
(E10, E11).
If no
RT1
command is assigned, ACC/DEC time 1 (F07, F08) takes effect by default.
Input terminal command
RT1
Acceleration/deceleration time
OFF
Acceleration/deceleration time 1 (F07, F08)
ON
Acceleration/deceleration time 2 (E10, E11)
5-44