96
q
Turn OFF the power to the printer. (See
section 5.2.2.)
w
Remove the sub-tank cover.
e
Turn the P1-1 filter holder 90 degrees
counterclockwise, lift it out and place it on
the tray.
Do not let the solution drip or run.
5.10
Replacing the Circulation Filters
The circulation filters are provided to filter out any dirt or sediment contained in the
circulating solutions in the processing tank. The filters should be replaced once a
month, irrespective of how much paper has been processed.
Processing solutions may irritate the eyes and skin. When handling processing solutions, wear
protective goggles, a rubber apron, rubber gloves, rubber boots and other protective gear, as
appropriate, to prevent the any solution from coming in contact with the body. Always wash hands
well after handling the processing solutions.
IMPORTANT
· If the circulation filters are not replaced, the circulation of processing solutions will be reduced.
This will cause impaired temperature control and poor processing performance.
· To prevent processing solution contamination, replace the filters one at a time in the following
order: P1-1
➝
P1-2
➝
P2-1
➝
P2-2
➝
PS1
➝
PS2
➝
PS3
➝
PS4.
GD1316
Sub-tank Cover
GD1277
P1-1 Filter Holder
Содержание FRONTIER 390
Страница 11: ...9 1 OPERATIONAL SAFETY AND USE CONDITIONS 9 GD1550 1 ...
Страница 12: ...10 10 GD1559 1 3 2 Caution Label Locations on Printer Paper Processor ...
Страница 13: ...11 1 OPERATIONAL SAFETY AND USE CONDITIONS 11 GD1560 ...
Страница 19: ...17 1 OPERATIONAL SAFETY AND USE CONDITIONS 17 GD1550 2 ...
Страница 165: ...169 10 LIST OF CONSUMABLES 10 1 Scanner 170 10 2 Printer Processor 171 ...
Страница 168: ...173 11 INDEX 5 1 Index 174 5 2 Index of Basic Operating Instructions 176 ...