2 - 116
MASTER-KxxxS
MASTER-KxxxS CNET
GLOFA CNET / GM series CPU
Set the memory to the extent of the memory range of each PLC model.
Use TYPE number to assign indirect memory for macro programs.
Memory
TYPE
Remarks
P
(input/output)
0
Input : read only
PW as word device
M
(relay)
1
MW as word device
L
(link relay)
2
LW as word device
K
(keep relay)
3
KW as word device
F
(special relay)
4
Read only
FW as word device
T
(timer/current value)
5
C
(counter/set value)
6
D
(data register)
7
TC
(time/cortact)
9
CC
(counter/contact)
10
Memory
TYPE
Remarks
M
(internal memory)
0
MW as word device
Q
(output)
1
QW as word device
I
(input)
2
IW as word device
43 LG PLC
Memory
TYPE
Remarks
P
(input/output)
0
Input : read only
M
(relay)
1
L
(link relay)
2
K
(keep relay)
3
F
(special relay)
4
Read only
T
(timer/current value)
5
C
(counter/set value)
6
D
(data register)
7
TC
(time/cortact)
9
CC
(counter/contact)
10