5-1
Chapter 5 FREQUENCY CONTROL WITH PULSE RATE INPUT
The pulse rate input feature supplies a frequency command to the inverter in pulse trains. Two pulse
input modes are available--B phase pulse (with signs) and forward/reverse rotation pulse trains.
The frequency control with pulse rate input can be enabled concurrently with the speed and
positioning controls with PG.
5.1 Specifications
Table 5.1 lists the specifications of frequency control with pulse rate input.
Table 5.1 Specifications for Pulse Train Inputs
Item Specifications
Reference frequency range
0 to 400 Hz
Frequency accuracy
±
0.2% of maximum frequency
Output circuits
Open collector
Complementary
Input pulse level
5 VDC
±
10%
Maximum cable length and maximum input pulse rate
20 m, 30 kp/s
5.2 Terminal
Functions
Table 5.2 lists terminal specifications.
Table 5.2 Terminal Specifications
Terminal
symbol
Name Descriptions
PI
Power input terminal
Receives power for the PG from an external source.
PO
Power output terminal
Outputs power to the PG.
CM
Common terminal
Common terminal for the PG power.
XA
Command input terminal
for A phase pulse train
Receives an A phase feedback pulse train.
XB
Command input terminal
for B phase pulse train
Receives a B phase feedback pulse train.
XZ --
Reserved.
The pulse count of [XA] and [XB] terminal inputs can be displayed on the keypad by
using Menu #4 "I/O Checking," Check item 4_15. For details, refer to the inverter’s
instruction manual. (See the description of function code E52.)
5.3 Function Code List
Table 5.3 lists function codes to be used for pulse rate input. Mounting the PG interface card can
display o codes.
Table 5.3 Related Function Codes
Code
Name
Data setting range
Unit
Default
setting
Change
when
running
F01
(C30)
Frequency Command 1
(Frequency Command 2)
0 to 3, 5. 7. 11, 12
-
0
(2)
N
o01
Command/Feedback
Input
(Input mode)
0, 1, 2,
10, 11, 12
20, 21, 22
- 0 N
o06
Command:
(Pulse train input)
(Filter time constant)
0.000 to 5.000
s
0.005
Y
o07
(Pulse count factor 1)
1 to 9999
-
1
N
o08
(Pulse count factor 2)
1 to 9999
-
1
N