Keys 

Functions 

 

Set key which works as follows according to the operation modes. 

 In Running mode: 

Pressing this key switch to the selection screen of the LCD monitor content. 

 In Programming mode: Pressing this key establishes the selected items and data being changed. 

 In Alarm mode: 

Pressing this key switch to the alarm detailed information screen. 

 

Pressing this key call up the HELP screen according to the current display state. 

Holding it down for 2 seconds toggles between the remote and local modes. 

 

Pressing this key starts running the motor in the forward rotation (when local mode). 

 

Pressing this key starts running the motor in the reverse rotation (when local mode). 

 

Pressing this key stops the motor (when local mode). 

 

7.2.2 

Keypad menus 

Table 8.6: Keypad menus organization and its function. 

Main 

Menu 

Sub-Menu 

Hierarchy 

indicator 

Principal Functions 

0. Quick Setup: Shows only frequently used function codes. 

 

— 

— 

PRG>0 

 

1. Start-up: Sets functions for initial settings. 

 

Language 

PRG>1>1 

Sets language to be displayed on LCD monitor. 

 

Select application 

PRG>1>2 

Allows individual initialization of function codes that are grouped 

by application. 

 

Display settings 

PRG>1>3 

Selects content to be displayed on LCD screen. 

2. Function Code: Setting screens related to function codes, such as setting/copying function code data. 

 

Set data 

PRG>2>1 

Allows function code data to be displayed/changed. 

 

Confirm data 

PRG>2>2 

Allows confirmation of function code settings. 

 

Confirm revised data 

PRG>2>3 

Allows  confirmation  of  function  code  changes  from  factory-

default settings. 

 

Copy data 

PRG>2>4 

Reads,  writes  and  verifies  function  code  data  between  the 

inverter and the keypad. 

 

Initialize data 

PRG>2>5 

Restores function code data values to factory-default settings. 

3. INV Information: Allows monitoring of inverter operational status. 

 

Operation monitor 

PRG>3>1 

Displays operational information. 

 

I/O checking 

PRG>3>2 

Displays external interface information. 

 

Maintenance information 

PRG>3>3 

Displays cumulative run time and other information used during 

maintenance. 

 

Unit information 

PRG>3>4 

Allows  confirmation  of  inverter  type,  serial  number  and  ROM 

version. 

 

Travel direction counter 

PRG>3>5 

Allows confirmation and setting of travel direction counter. This 

function provides the information for replacing wire/rope. 

4. Alarm Information: Displays alarm information. 

 

Alarm history 

PRG>4>1 

Lists  alarm  history  (newest  +  3  previous).  Also  this  allows  you  to 

view  the  detail  information  on  the  running  status  at  the  time  when 

alarm occurred. 

5. User Configure: Allows any settings to be made. 

 

Quick setup selection 

PRG>5>1 

Allows function codes to be added to or deleted from the "Quick 

Setup". 

6. Tools: Various functions 

 

Customizable logic monitor 

PRG>6>1 

Previews status of each step in customizable logic. 

 

Load Factor Measurement 

PRG>6>2 

Allows measurement of the operational status  of the maximum 

output current and average output current. 

 

Communication Debugging 

PRG>6>3 

Allows monitoring and setting of function codes for 

communication (S, M, W, X, Z, etc.) 

 
 

7.2.3 

Example of function setting 

 

Содержание FRENIC-Lift FRN0010LM2C-4E

Страница 1: ...Starting Guide Dedicated inverter for lift applications with induction motor in open loop 3 ph 400 VAC 4 0 15 kW SG_LM2C_EN_1 0 0...

Страница 2: ...Page 2 of 28 Fuji Electric Europe GmbH Version Changes applied Date Written Checked Approved 1 0 0 First release 25 10 2019 J Alonso 1 0 1 Small text corrections 25 11 2019 J Alonso C Arjona J Catal...

Страница 3: ...re configuration 13 7 Keypad operation 14 7 1 TP E1U Basic keypad 14 7 1 1 Led monitor keys and LED indicators on the keypad 14 7 1 2 Overview of operation modes 15 7 1 3 USB connectivity 15 7 1 4 TP...

Страница 4: ...s bodily injuries Failure to heed the information indicated by this symbol may lead to dangerous conditions possibly resulting in minor or light bodily injuries and or substantial property damage Fail...

Страница 5: ...parts in the main circuit their insulation coat may break for any reasons In such a case ensure the signal control wire is protected from making contact with any high voltage cables Doing so could ca...

Страница 6: ...es that they comply with the essential requirements of the Electromagnetic Compatibility EMC Directive 2014 30 EU and the Low Voltage Directive 2014 35 EU issued by the Council of the European Communi...

Страница 7: ...13849 1 PL e EN60204 1 stop category 0 EN61800 5 2 STO SIL3 EN62061 SIL3 Low Voltage Directive EN61800 5 1 Over voltage category 3 EMC Directive with external EMC filter EN12015 EN12016 EN 61800 3 A1...

Страница 8: ...0 195 0 FRN0015LM2C 4E FRN0019LM2C 4E FRN0025LM2C 4E FRN0032LM2C 4E 2 160 0 360 0 195 0 FRN0010LM2C 4E to FRN0025LM2C 4E FRN0032LM2C 4E 4 Removal and attachment of front cover In order to remove prop...

Страница 9: ...ed in table 5 1 Table 5 1 Power terminals description Terminal label Description of the power terminals L1 R L2 S L3 T 3 phase supply input from mains supply U V W 3 phase motor connection for inducti...

Страница 10: ...C07 1 0 0 L15 4 100 Intermediate speed 2 C08 1 0 1 L16 5 101 Intermediate speed 3 C09 1 1 0 L17 6 110 Intermediate speed 4 C10 1 1 1 L18 7 111 High speed 1 C11 In case that lift controller signals doe...

Страница 11: ...proper usage of EN terminals is recommended In figure 5 6 an example of wiring is shown Terminal Function description of the digital inputs FWD Clockwise rotation of the motor seen from the shaft sid...

Страница 12: ...tact rating 250 VAC 0 5 A 30 VDC 0 5A Y4A Y4C Main MC control function SW52 2 Contact rating 250 VAC 0 5 A 30 VDC 0 5A Y3A Y3C Speed detected function FDT Contact rating 250 VAC 0 5 A 30 VDC 0 5A 5 4...

Страница 13: ...d NPN SINK SOUCE SW2 Terminating resistor of RS 485 communications port 1 Port 1 is in RJ 45 connector When keypad or converter for FRENIC Loader is used set SW2 to OFF position When DCP or Modbus com...

Страница 14: ...want to do in each mode as follows In Running mode Pressing this key switches the information to be displayed Monitor data fixed on E52 In Programming mode Pressing this key displays the function cod...

Страница 15: ...rm has occurred Running mode Monitor of running status Power ON Release of a heavy alarm Figure 8 2 Status Transition between Operation Modes Simultaneous keying Simultaneous keying means pressing two...

Страница 16: ...Maintenance Information 5 CHE Display maintenance information including cumulative run time Cumulative RUN time 5_00 DC link bus voltage 5_01 Max temperature inside the inverter 5_02 Number of startu...

Страница 17: ...alarm has occurred Flashing ON A light alarm has occurred But inverter can continue running Red Shows the alarm state heavy alarm OFF No heavy alarm has occurred Flashing A heavy alarm has occurred In...

Страница 18: ...firmation of function code settings 3 Confirm revised data PRG 2 3 Allows confirmation of function code changes from factory default settings 4 Copy data PRG 2 4 Reads writes and verifies function cod...

Страница 19: ...lect a target menu item by using keys Then press key Adjust data value by using keys Then press key to store data into memory Inverter memorizes changed data and moves next screen automatically Invert...

Страница 20: ...as to be performed Auto tuning will get special data from the motor like no load current P06 stator resistance P07 stator inductance P08 and slip frequency P12 In order to perform an auto tuning follo...

Страница 21: ...s and S curves are used we have to enter in Table 10 1 from the left hand column in the row of the speed that is settled before the change ex C08 and look up in the column pointing at the target speed...

Страница 22: ...of brake control will be activated and the mechanical brake opens releases after t2 time elapses delay time to the reaction of contactors coil After completion of time F24 the speed set point will be...

Страница 23: ...oad than with half load it means that the slip is not enough We need to give more slip when the cabin is empty with more slip the lift will go faster than without load in driving condition in this cas...

Страница 24: ...20 s Increase F24 Max F24 1 5 s Too high torque Reduce P06 P06 30 70 of P03 Not related to inverters setting Check brake operation Check guides oil alignment etc Check car fixation shoes TROUBLESHOOT...

Страница 25: ...rake reaction too soft Increase F21 Max F21 90 Check F22 0 00s Insufficient torque Increase P06 P06 30 70 of P03 Increase F09 Max F09 5 0 Not related to inverters setting Check security chain operatio...

Страница 26: ...fective Ambient temperature too high OH2 External Alarm Digital input programmed with value 9 THR is not active OH3 Inverter internal overheat Check temperature inside electrical cabinet OH4 Motor pro...

Страница 27: ...communication error CAN bus disconnected from the inverter Electrical noise connect cable shield Terminating resistor not connected bbE Brake status monitoring according to EN81 20 Brake state differ...