Page
16
of
28
Fuji Electric Europe GmbH
3.
Drive Monitoring (3.oPE)
Displays the running information required for maintenance or test running.
Output frequency
3_00
Output current
3_02
Output torque
3_04
Motor speed
3_08
4.
I/O Checking (4.I_o)
Display external interface information.
Segments
LED 4
LED 3
LED 2
LED 1
a
30A/B/C
Y1-CMY
X7
FWD
b
---
Y2-CMY
---
REV
c
---
Y3-CMY
---
X1
d
---
Y4-CMY
EN1&2
X2
e
---
Y5A-Y5C
---
X3
f
---
---
(XF)*
X4
g
---
---
(XR)*
X5
dp
---
---
(RST)*
X6
If all terminal input signals are OFF (open), segment "g" on all of LED1 to LED4 will
light ("
– – – –").
(XF)*, (XR)*, (RST)* Only for communications.
This information can be monitored in 4_00 menu.
5.
Maintenance Information (5.CHE)
Display maintenance information including cumulative run time.
Cumulative RUN time
5_00
DC link bus voltage
5_01
Max. temperature inside the inverter
5_02
Number of startups
5_08
6.
Alarm information (6.AL)
Display the recent four alarm codes. You can refer to the running information at the time when the alarm
occurred.
Error sub code
3_21
7.
Data Copying (7.CPY)
Allows you to read or write function code data, as well as verifying it. Customizable logic parameters are
copied as well.
Example of Function setting
Example of function code data changing procedure is shown in Figure 8.4, in that case F01 is set from
0 to 2.
Figure 8.4. Function setting procedure
You can move the cursor when changing function code data by holding down the
key for 1 second or longer.