DigiTemp User Manual 

Chapter 1  Operation 

 

page 7 

1.3

 

Connection 

The DigiTemp can be supplied with or without a connector. Cable wire colour coding and FTS standard 
connector

1

 pinouts are shown in the table and diagram below: 

Wire colour 

Pin

1

 

Function 

Red 

+12 V DC power supply 

White 

Data 

Black 

Ground 

 

If the DigiTemp is supplied without a connector, the user is responsible for connecting the sensor to the data 
collection platform. A user can attach their own connector, or connect the cable via a terminal strip, or directly 
wire it to device electronics. 

1.4

 

Operation 

The FTS DigiTemp is an SDI-12 device and is powered by the +12 V DC power supply on the SDI-12 bus.  

For details on the SDI commands used by the sensor, see Chapter 2 SDI Commands. 

1.5

 

Configuration 

The DigiTemp is shipped with default address 0 (unless shipped as part of an integrated FTS system). The only 
configuration available is to change this address if necessary in systems with more than one SDI-12 sensor on 
the same bus. Refer to section 2.3.3 Change Address for instructions on setting the sensor’s address.  

1.6

 

Calibration and maintenance 

Calibration is never required. Maintenance consists of periodic checking for cable wear. 

Please contact FTS technical support (see manual front pages) if the unit ceases to operate properly. 

 

                                                      

1

 Waterproof military-style bayonet connector 851-06JC8-3AP50; FTS part number 520-83AP; compatible with FTS 

Axiom dataloggers. 

Содержание DigiTemp

Страница 1: ...1 800 548 4264 www ftshydrology com 700 DigiTemp Rev 1 0 24 Nov 2011 DigiTemp SDI 12 Submersible Digital Temperature Sensor User Manual...

Страница 2: ...Contact information FTS 1065 Henry Eng Place Victoria B C V9B 6B2 CANADA www ftshydrology com Toll free 1 800 548 4264 Local 250 478 5561 Technical support support ftshydrology com...

Страница 3: ...Revision History Date Person Description 24 Nov 2011 RG First released version 28 Nov 2011 RG Late corrections...

Страница 4: ...3 Connection 7 1 4 Operation 7 1 5 Configuration 7 1 6 Calibration and maintenance 7 Chapter 2 SDI Commands 8 2 1 Notation for SDI commands 9 2 2 Commands recognized by DigiTemp 9 2 3 General SDI com...

Страница 5: ...Chapter 1 Operation Chapter contents 1 1 General description 6 1 2 Installation 6 1 3 Connection 7 1 4 Operation 7 1 5 Configuration 7 1 6 Calibration and maintenance 7...

Страница 6: ...these steps 1 Place the sensor in a location where it is continuously immersed in a representative sample of the water to be monitored usually a well mixed locale 2 The sensor may be mounted on an ob...

Страница 7: ...s powered by the 12 V DC power supply on the SDI 12 bus For details on the SDI commands used by the sensor see Chapter 2 SDI Commands 1 5 Configuration The DigiTemp is shipped with default address 0 u...

Страница 8: ...2 3 General SDI commands 9 2 3 1 Address Query 2 3 2 Acknowledge Active 2 3 3 Change Address 2 3 4 Send Identification 2 4 SDI Data commands 10 2 4 1 Start Measurement 2 4 2 Start Concurrent Measureme...

Страница 9: ...Commands recognized by DigiTemp The table below provides a quick reference to the commands recognized by the DigiTemp For details on these commands see the following sections Command name Command code...

Страница 10: ...address String Note Cmd 0 request the device at address 0 to confirm it is active Resp 0 a device is present at address 0 2 3 3 Change Address This command changes a sensor s SDI address String Note C...

Страница 11: ...Table 2 String Note Cmd 3C or 3CC start a concurrent measurement on sensor at address 3 without or with CRC in data response respectively Resp 300302 3 device SDI address 003 measurement delay until d...

Страница 12: ...ata is returned Cmd 1RC perform a continuous measurement read on sensor at address 3 with CRC code in data response Resp 1MSA 1 sensor SDI address MSA CRC code DigiTemp is not a continuous measurement...

Страница 13: ...Chapter 3 Technical specifications...

Страница 14: ...may be less accurate Responsiveness Time constant 0 57 min reaches 95 of final value in 1 7 min 99 in 2 9min Measurement time 3 s Power supply voltage 12 V DC nominal range 9 6 V 18 6 V Standby curre...

Отзывы: