DigiTemp User Manual 

Chapter 2  SDI Commands 

 

page 12 

Cmd 

3D0! 

request data from previous measurement command 

Resp 

3+11.4+52.5DZF 

3

 

sensor SDI address 

+11.4

  temperature in degrees Celsius 

+52.5

  temperature in degrees Fahrenheit 

DZF

 

CRC code 

2.4.4

 

Continuous Measurement 

This command is not supported by the sensor. The response of the sensor to a Continuous Measurement 
command is shown below. 

 

String 

Note 

Cmd 

1R! 

perform a continuous measurement read on sensor at 

address 3 

Resp 

1

 

sensor SDI address 

DigiTemp is not a continuous measurement device. No 

data is returned. 

Cmd 

1RC! 

perform a continuous measurement read on sensor at 

address 3, with CRC code in data response 

Resp 

1MSA 

1

 

sensor SDI address 

MSA

 

CRC code 

DigiTemp is not a continuous measurement device. No 

data is returned. 

2.4.5

 

Start Verification 

This command is not supported by the sensor. The response of the sensor to a Start Verification command is 
shown below. 

 

String 

Note 

Cmd 

3V! 

start verification on sensor at address 3 

Resp 

30000 

3

 

device SDI address 

000

 

measurement delay (until data is ready; seconds) 

0

 

no data is returned 

2.5

 

Description of measured values 

Measured value 

Measurement 
resolution 

Description 

Temperature (C) 

2 decimal places 

Temperature in degrees Celsius 

Temperature (F) 

2 decimal places 

Temperature in degrees Fahrenheit 

 

Содержание DigiTemp

Страница 1: ...1 800 548 4264 www ftshydrology com 700 DigiTemp Rev 1 0 24 Nov 2011 DigiTemp SDI 12 Submersible Digital Temperature Sensor User Manual...

Страница 2: ...Contact information FTS 1065 Henry Eng Place Victoria B C V9B 6B2 CANADA www ftshydrology com Toll free 1 800 548 4264 Local 250 478 5561 Technical support support ftshydrology com...

Страница 3: ...Revision History Date Person Description 24 Nov 2011 RG First released version 28 Nov 2011 RG Late corrections...

Страница 4: ...3 Connection 7 1 4 Operation 7 1 5 Configuration 7 1 6 Calibration and maintenance 7 Chapter 2 SDI Commands 8 2 1 Notation for SDI commands 9 2 2 Commands recognized by DigiTemp 9 2 3 General SDI com...

Страница 5: ...Chapter 1 Operation Chapter contents 1 1 General description 6 1 2 Installation 6 1 3 Connection 7 1 4 Operation 7 1 5 Configuration 7 1 6 Calibration and maintenance 7...

Страница 6: ...these steps 1 Place the sensor in a location where it is continuously immersed in a representative sample of the water to be monitored usually a well mixed locale 2 The sensor may be mounted on an ob...

Страница 7: ...s powered by the 12 V DC power supply on the SDI 12 bus For details on the SDI commands used by the sensor see Chapter 2 SDI Commands 1 5 Configuration The DigiTemp is shipped with default address 0 u...

Страница 8: ...2 3 General SDI commands 9 2 3 1 Address Query 2 3 2 Acknowledge Active 2 3 3 Change Address 2 3 4 Send Identification 2 4 SDI Data commands 10 2 4 1 Start Measurement 2 4 2 Start Concurrent Measureme...

Страница 9: ...Commands recognized by DigiTemp The table below provides a quick reference to the commands recognized by the DigiTemp For details on these commands see the following sections Command name Command code...

Страница 10: ...address String Note Cmd 0 request the device at address 0 to confirm it is active Resp 0 a device is present at address 0 2 3 3 Change Address This command changes a sensor s SDI address String Note C...

Страница 11: ...Table 2 String Note Cmd 3C or 3CC start a concurrent measurement on sensor at address 3 without or with CRC in data response respectively Resp 300302 3 device SDI address 003 measurement delay until d...

Страница 12: ...ata is returned Cmd 1RC perform a continuous measurement read on sensor at address 3 with CRC code in data response Resp 1MSA 1 sensor SDI address MSA CRC code DigiTemp is not a continuous measurement...

Страница 13: ...Chapter 3 Technical specifications...

Страница 14: ...may be less accurate Responsiveness Time constant 0 57 min reaches 95 of final value in 1 7 min 99 in 2 9min Measurement time 3 s Power supply voltage 12 V DC nominal range 9 6 V 18 6 V Standby curre...

Отзывы: