The setting range is from 36.0V to 48.0V.
The setting range is from 48.0V to 64.0V.
04
Float voltage
The setting range is from 12.0V to 16.0V.
The setting range is from 24.0V to 32.0V.
The setting range is from 36.0V to 48.0V.
The setting range is from 48.0V to 64.0V.
05
Battery
rated
voltage
Auto(Default)
If “AUO” is selected, connected battery
voltage system will be automatically
detected.
If “12V” is selected, the unit is considered
as 12V battery system.
If “24V” is selected, the unit is considered
as 24V battery system.
If “36V” is selected, the unit is considered
as 36V battery system.
If “48V” is selected, the unit is considered
as 48V battery system.
06
Battery
C.V.
Charging
duration
(Default)
The setting range is form 5 minutes to
900 minutes.
Increment of each short press is 5
minutes. It will jump back to 5 minutes
after 900 is achieved.
07
BTS temperature
compensation
ratio
0mV(Default)
The setting range is from 0mV to 60.0mV.
Increment of each short press is 0.1mV.
The value will jump back to 0mV after
60.0mV is achieved.
For each 12V Battery, the derated battery
charging voltage is followed the below
formula:
(Battery temperature-25
℃
)
*BTS ratio
08
Battery
equalization
enable/disable
Disable(Default)
Enable
09
Battery
equalization
voltage
The setting range is from 12.0V to 16.0V.
The setting range is from 24.0V to 32.0V.