Menu - Color Menu
Color Menu
Function
ColorSystem
User
Scope
LUT Mode
Normal
Video
Range
SMPTE Full 4-1019
Color
Gamut
BT.709
System
Temperature
Default
OSD
EOTF
Gamma 2.4
Luminance Mode
100
Luminance Custom
45
ColorSystem
The monitor features 5 Color System selections: DEFAULT, GaiaColor, LightSpace, CalMAN, and
NONE. On the XM652U, XM651U, XM650U, XM552U, and XM551U the factory calibrations are
stored in the DEFAULT Color System. LightSpace and CalMAN Color System options are provided
as additional memory place holders to store custom end-user calibrations using LightIllusion
(LightSpace / ColourSpace) or CalMAN calibration software. The GaiaColor selection is reserved for
future development and should not be used at this time on XM WOLED displays. Please leave the
ColorSystem set to Default unless you have specifically saved your own user generated calibration
LUTs to the LightSpace or CalMAN memory banks.
LUT Mode
Does not apply to GaiaColor Color System. In Default, LightSpace, or CalMAN modes select Normal
or Advanced. Normal Mode enables both calibration and look LUT positions. Advanced Mode provides
larger cLUT size support, but limits look LUT and ancillary feature support (e.g. scopes).
In Normal Mode 6 LUT positions are accessible at a time as follows:
Front DIT 1D LUT -> DIT 3D LUT -> Post DIT 1D LUT-> Front Calibration 1D LUT -> Calibration 3D LUT
-> Post Calibration 1D LUT
In Normal Mode all 1D LUTs are 4096 entry point using 12bit values in the Flanders.lut format and all
3D LUTs are 17x17x17.cube format using only the header LUT_3D_SIZE 17.
The DIT LUT positions should be used for technical transforms or look LUTs, calibration LUTs should
normally only be stored in the Calibration LUT positions.
In Advanced Mode 3 LUT positions are accessible at a time as follows:
Front Calibration 1D LUT -> Calibration 3D LUT -> Post Calibration 1D LUT
In Advanced Mode all 1D LUTs are 4096 entry point using 12bit values in the Flanders.lut format and
the 3D LUT is 33x33x33.cube format using only the header LUT_3D_SIZE 33.
LUTs can be saved to the display using the IP Remote Utility.
Application Note: LUTs are applied within the range active on the monitor’s color menu.