background image

 

Semi Commercial Reverse 

Osmosis Water Filter System 

35L/Hr – GT1-20LS 

 

Contents 

Technical Overview ...................................................................................................................................... 2 

I. Important Notes ..................................................................................................................................... 2 

II. Before You Purchase/Open .................................................................................................................. 2 

III. Space Requirements ............................................................................................................................ 2 

IV. Before You Begin Installation ............................................................................................................... 3 

V. What is Reverse Osmosis ..................................................................................................................... 3 

VI. Example Applications .......................................................................................................................... 3 

VII. Installation with other Systems ............................................................................................................ 3 

Installation Introduction ................................................................................................................................. 4 

I. Site Preparation ..................................................................................................................................... 4 

II. Installation – Mounting .......................................................................................................................... 4 

III. Installation – Free-Standing ................................................................................................................. 4 

IV. Installing Connections – Quick Connect ............................................................................................... 4 

V. Filter Protection .................................................................................................................................... 5 

VI. Drain/Waste ......................................................................................................................................... 5 

VII. Cartridge Installation ........................................................................................................................... 5 

(a) Pre-Filters ........................................................................................................................................ 5 

(b) Membrane ........................................................................................................................................ 5 

(c) Post Filters ....................................................................................................................................... 6 

(d) De Ionising Post Filters .................................................................................................................... 6 

Connecting the System................................................................................................................................. 6 

I. Tubing .................................................................................................................................................... 6 

II. Power.................................................................................................................................................... 6 

Start Up & Operation .................................................................................................................................... 6 

I. Commissioning ...................................................................................................................................... 6 

II. General Operation ............................................................................................................................. 6 

III. Automation ........................................................................................................................................... 7 

Maintenance ................................................................................................................................................. 7 

I. Replacement Parts................................................................................................................................. 7 

II. Replacement Cartridges ....................................................................................................................... 7 

III. Parts List .............................................................................................................................................. 8 

Troubleshooting ............................................................................................................................................ 8 

 

Содержание GT1-20LS

Страница 1: ...ion Introduction 4 I Site Preparation 4 II Installation Mounting 4 III Installation Free Standing 4 IV Installing Connections Quick Connect 4 V Filter Protection 5 VI Drain Waste 5 VII Cartridge Insta...

Страница 2: ...are listed below If these conditions are not met the system may not be suitable for the application and may not function as specified These systems are designed for filtration on mains water for the r...

Страница 3: ...s which may require treating before the system Bore Water filtration is used when the water meets specific conditions where an RO unit will be suitable to remove elevated salt levels in the water gene...

Страница 4: ...tem to reduce negative effects on the pressure flow and performance of the system It is also recommended that the process water filtered water does not have to travel more than 2m elevation above the...

Страница 5: ...eated Before Spun Spun Before Carbon Highest Micron Before Lowest Micron As an example a common filter set would be 5uM Polyspun 20uM Low Pressure Carbon 0 5uM Chloramine Reduction Carbon You would in...

Страница 6: ...int Measure a length of tubing from the outlet point of the system to your intended usage point or storage II Power The system is supplied with a 3 pin AU plug Install this into a GPO 10A min It is ad...

Страница 7: ...uce water When the outlet shuts off the high pressure switch will trip after a period of time similar to a household pump and then the system will shut down When the outlet is opened and the pressure...

Страница 8: ...r Filter Cartridge Check TDS 6 12 Months GT5 12S Mixed Bed DI Resin Check TDS 6 12 Months 1Kg per refill Pumps Solenoids Switches GT13 38LS 8200L Reverse Osmosis Booster Pump 200GPD 2 000Hr 12 Months...

Страница 9: ...ation 3 Contamination 1 The filters are dry packed the carbons alkaline filters will have fines on them 2 As previously stated Activated Coconut carbon will react with the water when new and will incr...

Страница 10: ...electrician can test the components to see if power is making it to the pumps...

Страница 11: ...of of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the use of replacement filters fittings and components supplied by FS...

Страница 12: ...f the system is installed on an open circuit a plumber may not be required in this case the system must be installed in accordance with the user manual and determined to be correctly installed by FSA...

Отзывы: