V. Filter Protection 

These systems are supplied with an inline Pressure Limiting Valve fitted to the inlet port of the system. This 
valve limits the pressure incoming to 50 psi (350 kPa). If your incoming pressure is below 350 kPa, you can 
remove the PLV as it may further reduce your incoming pressure. 

The system does not come standard with inlet fittings – this should be supplied by the installer unless the 
purchaser of the system included fittings in the original purchase. 

It is recommended that an anti-water hammer devise is installed on the house to dampen water hammer 
commonly caused by washing machines. It is best to install these devices at the point of hammer such as 
on the cold-water line at the washing machine or dishwasher for residential applications, or for commercial 
applications install near any electric solenoid valves. 

VI. Drain/Waste 

Reverse Osmosis Systems produce waste water due to the RO process. This water will need to be 
discarded in accordance with local government regulations. For applications where the feed water quality is 
fair (mains water) the waste water is able to be sent to sewage/septic. NOTE: for septic, consult with the 
manufacturer to ensure the increase water discharge is within specification for your septic system. In some 
cases where the feed water quality is good, the discharge water may be suitable for utility use and watering 
not food plants. It is best to check with the supplier before using the discharge water. If the feed water is 
high in salt, the waste water will be concentrated with higher levels of salt and may not be suitable for 
discharge into sewage or septic. 

If the waste water is not suitable for conventional septic or sewage, you will need to dispose of the water in 
a rubble pit or evaporation pit in compliance with local regulations. The waste water should not be allowed 
to flow into the environment unless permitted by local authority. 

VII. Cartridge Installation 

(a) Pre-Filters 

Cartridges should be installed in order of: Pleated Before Spun, Spun Before Carbon, Highest Micron 
Before Lowest Micron. 
As an example, a common filter set would be 5uM Polyspun, 20uM Low Pressure Carbon, 0.5uM 
Chloramine Reduction Carbon. You would install them in that order as per the above guideline. Usually We 
will invoice the filter in order of installation (reading down the invoice). 

Cartridges will need to have the outer plastic shrink wrapping removed before being installed. Maintain 
minimal contact with the surface of the carbon filter, handle by the end caps only to avoid contamination as 
carbon will absorb smells and oils from the skin. 

Gently lower the cartridge into the blue sump and locate the filter so the stem in the bottom of the sump 
inserts into the centre hole of the cartridge. Do not drop the filter in as this centre stem may break the 
plastic caps of the filters. Once the filter is located, screw the sump into the cap (in a vertical position). It 
can help to wobble the sump to help the filter locate into the guide lugs in the top of the cap. 

The caps should screw up rather smoothly with little resistance so it is usually suitable to firmly hand tighten 
the housings. If you encounter resistance before the housing is more than ¾ tightened you may not have 
the cartridge aligned with the guide lugs; remove the sump and line it up correctly before tightening. An 
opening spanner if provided with these systems and is only required for installation if hand tightening is not 
easily achieved or if slight leaking occurs. It is important not to overtighten the housings as this can lead to 
excessive stress on the cap thread which may cause damage to the housing long term. The spanner can 
be used to help unscrew the housing when filter changes are required as the housings are usually more 
difficult to unscrew over time being installed.  

(b) Membrane 

In some cases, the membrane may already be installed in the cannister.  

1. Disconnect the tubing from the screw cap end of the membrane housing, check the o-ring to ensure it is 
in good condition, if the o-ring gets stuck in the cap – remove it and install it on the housing. 
2. Unwrap the Reverse Osmosis Membrane and install it into the membrane housing, ensure that you only 

Содержание GT1-20LS

Страница 1: ...ion Introduction 4 I Site Preparation 4 II Installation Mounting 4 III Installation Free Standing 4 IV Installing Connections Quick Connect 4 V Filter Protection 5 VI Drain Waste 5 VII Cartridge Insta...

Страница 2: ...are listed below If these conditions are not met the system may not be suitable for the application and may not function as specified These systems are designed for filtration on mains water for the r...

Страница 3: ...s which may require treating before the system Bore Water filtration is used when the water meets specific conditions where an RO unit will be suitable to remove elevated salt levels in the water gene...

Страница 4: ...tem to reduce negative effects on the pressure flow and performance of the system It is also recommended that the process water filtered water does not have to travel more than 2m elevation above the...

Страница 5: ...eated Before Spun Spun Before Carbon Highest Micron Before Lowest Micron As an example a common filter set would be 5uM Polyspun 20uM Low Pressure Carbon 0 5uM Chloramine Reduction Carbon You would in...

Страница 6: ...int Measure a length of tubing from the outlet point of the system to your intended usage point or storage II Power The system is supplied with a 3 pin AU plug Install this into a GPO 10A min It is ad...

Страница 7: ...uce water When the outlet shuts off the high pressure switch will trip after a period of time similar to a household pump and then the system will shut down When the outlet is opened and the pressure...

Страница 8: ...r Filter Cartridge Check TDS 6 12 Months GT5 12S Mixed Bed DI Resin Check TDS 6 12 Months 1Kg per refill Pumps Solenoids Switches GT13 38LS 8200L Reverse Osmosis Booster Pump 200GPD 2 000Hr 12 Months...

Страница 9: ...ation 3 Contamination 1 The filters are dry packed the carbons alkaline filters will have fines on them 2 As previously stated Activated Coconut carbon will react with the water when new and will incr...

Страница 10: ...electrician can test the components to see if power is making it to the pumps...

Страница 11: ...of of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the use of replacement filters fittings and components supplied by FS...

Страница 12: ...f the system is installed on an open circuit a plumber may not be required in this case the system must be installed in accordance with the user manual and determined to be correctly installed by FSA...

Отзывы: