1.11   K3000 Menu Summary Tree 
 

Filter Menu 

Setup  and Tech Modes

Info Mode

[With comput er ON, press and hold FILTER button]

Filter
Clean
Dispose
Drain to Pan
Fill Vat From Pan

Long Name
Short Name
Cooking Mode
1 Time
1 Tempr
1 Flex
1 Pressure Solenoid
2 Time
1 Alarm Time
1 Alarm Name
1 Alarm Mode
1 Alarm Tone
2 Alarm Time
After Cooking Setpoint
Filter Lockout
Quantity
Head Count
Instant On

Product Setup

Select Product

Filter Stats
Review Usage
Last Load

E-Log

Change Password

Log of last 10 error codes

………………………………………………………………………………………………………….. 

1.5

…….………...…………….....………………………………………………………….. 

1.4

………………...………………………...………………………………………..……………………….. 

1.3

..….………...…….....………..……………………………………………….. 

1.9 - 1.10

……….………….………………………….. 

1.4

[With comput er OFF, press and hold 

(check) but ton]

Oil Stats

[Enter 1724 ]

Vat Setup

System

….………………...…...…….....………………………………………………………….. 

1.4

Language
2

nd

 Language

Locale (CE or Non-CE)
Energy
Type (Vat)
System Volume (Level)
Tempr Format (F or C)
Exit Melt Tempr
Setback Tempr
Fresh Oil
Waste
Recovery Alarm

Time/Date

………...…..……...…….....………………………………………………………….. 

1.4

Filter

…………………....………...…….....………………………………………………………….. 

1.4

Global Filter Count
EOD Filter Time
1 Polish Timer
1 Polish Time
1 Polish Duration
1 Polish Delay Time
1 Polish Start Tempr
2 Polish Timer
2 Polish Time
2 Polish Duration
2 Polish Delay Time
2 Polish Start Tempr

…...………………....………………………………………………….. 

1.4

Edit Alarm Names

…...………………....………………………………………………….. 

1.4

Tech Mode

[With comput er OFF, press and hold 

(check) but ton 10 seconds, displays Product Setup]

[Enter 3228 ]

[Enter 1650 ]

Clear E-Log
Clear Passwords
Lane Count
Hi-Limit Test

DST (Daylight Savings Time) Setup

..………...….………………………….. 

1.4

[Only adjustable by Entering 3228 ]

 

Содержание YUM K3000

Страница 1: ...w information and models are released Visit our website for the latest manual Part Number FRY_IOM_8196647 11 2021 8196647 Original Instructions CAUTION READ THE INSTRUCTIONS BEFORE USING THE FRYER Kee...

Страница 2: ...product button to cancel alarm Press and hold product button to cancel cook cycle Responding to Polish Prompt Controller displays Polish Now alternating with Yes No Press Yes button under Yes display...

Страница 3: ...st dispose Total heads last dispose Number Press This is the number of heads cooked since the last dispose Last dispose date Press This is the date of the last dispose TEMP 300F TODAY Number Hrs Press...

Страница 4: ...ss This is the total number of cooks since the last usage reset QUIT COOKS Number Press This is the total amount of cooks that were cancelled since the last reset usage On HOURS Number Press This is t...

Страница 5: ...Controller displayed press System volume 9 Sets sound level for Controller Enter level 1 9 0 Lowest 9 Loudest Press Tempr format F Press to scroll choices F for Fahrenheit C for Celsius Press Exit Me...

Страница 6: ...press the Exit Scan button three times to return the controller to OFF filter Blank Press Global filter count 20 Press Changes the total number of cooks that occur before a filter prompt The default...

Страница 7: ...ange code use 10 for 0 Press Vat setup Current code 3228 Use numbered buttons to change code use 10 for 0 Press Exit Exit Press button once and press to scroll to System Time Date Filter E Log Change...

Страница 8: ...ue when complete OPEN RETURN VALVE Open return valve Polishing 5 minute countdown timer None required Fill vat YES Press YES CLOSE DRAIN VALVE CONFIRM Close drain valve and press CONFIRM filling None...

Страница 9: ...ion Action Polish Now Yes NO Respond to prompt with button push Press YES or NO Yes produces a filter detailed below No delays filter and cooking continues Add FILTER POWDER CONFIRM Add filter powder...

Страница 10: ...d name of the product COOKING MODE SINGLE SETPOINT Segmented If multiple setpoint or segmented cooking is desired press MULTIPLE SETPOINT and go to 1 9 and follow the instructions Non Segmented Leave...

Страница 11: ...ort none The duration of the audible alarm is optional Navigate choice with arrow buttons under display 2 Alarm Time Time The second point in the cook cycle an alarm sounds 2 Alarm Name Shake stir num...

Страница 12: ...previously entered time Enter 0 00 Press 1 Alarm TIME 0 00 or previously entered time Subtract the time from the starting cook time when the alarm should sound Example If a cook time is 5 00 and the...

Страница 13: ...first cooking segment 2 minutes and the setpoint of the first temperature change Step 3 sets the duration of the second cooking segment 4 minutes and the setpoint of the second temperature change Ste...

Страница 14: ...s are entered at the point in the countdown they are desired The example below is for alarms at 11 00 6 00 and 2 00 on the countdown clock the alarms will occur two seven and 11 minutes into the 13 mi...

Страница 15: ...rs 2 Time 0 00 or previously entered time Enter time remaining after first temperature change see page 1 11 and press 2 Tempr 0 00 or previously entered temperature Enter first temperature change and...

Страница 16: ...s the alarm time Enter that time for shaking stirring etc Press 2 Alarm name name Press to scroll through choices and press 2 alarm mode Manual or auto Choose mode with and press 2 Alarm Tone Short me...

Страница 17: ...omputer OFF press and hold check button Oil Stats Enter 1724 Vat Setup System 1 4 Language 2nd Language Locale CE or Non CE Energy Type Vat System Volume Level Tempr Format F or C Exit Melt Tempr Setb...

Страница 18: ...a small component may often be indicative of potential failure or incorrect functioning of a more important component or system If you are in doubt as to the proper action to take do not hesitate to...

Страница 19: ...all your FAS for assistance Controller displays Hi temp Frypot temperature is more than 40 F 4 C Press the power button to turn off fryer and let cool before returning power to fryer If issue continue...

Страница 20: ...rain valve switch plugged vacuum pressure switch failed blower motor Check drain valve high limit vacuum pressure switch blower motor If it continues shut the fryer down and call your FAS for assistan...

Страница 21: ...reading is out of range E05 HOT HI 1 High limit temperature is past more than 410 F 210 C or in CE countries 395 F 202 C E06 HEATING FAILURE A component has failed such as controller interface board c...

Страница 22: ...3 318 865 1711 WWW FRYMASTER COM EMAIL FRYSERVICE WELBILT COM 2021 Welbilt Inc except where explicitly stated otherwise All rights reserved Continuing product improvement may necessitate change of spe...

Отзывы: