6-3
6.2.2 Error Messages and Display Problems
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Controller displays
low temp
or
LO
.
Frypot temperature has dropped
more than 30°F (17°C) lower than
setpoint in idle mode or 45°F
(25°C) in cook mode.
This display is normal for a short while if a
large batch of frozen product is added to the
frypot or if the fryer is not heating properly. If
the issue persists call your FAS for assistance.
Controller displays
Hot hi-1
.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
Shut the fryer down immediately and call your
FAS for assistance.
Controller displays
Hi
temp.
Frypot temperature is more than
40 ºF (4ºC).
Press the power button to turn off fryer and let
cool before returning power to fryer. If issue
continues call your FAS for assistance.
CM III.5 displays
HI
.
Fryer is more than 21ºF (12ºC)
above setpoint.
This display is normal if the fryer setpoint has
been changed to a lower temperature. The
display should revert to the normal four
dashes when the frypot temperature cools to
the setpoint. If the setpoint has not been
changed, this indicates a problem with the
temperature control circuitry. Turn the fryer
off and call FAS.
Controller displays
RECOVERY
FAULT/ YES
and
alarm sounds.
Recovery time exceeded maximum
time limit.
Clear error and silence the alarm by pressing the
(YES) button. Maximum recovery time is
2:25. If the error continues call your FAS for
assistance.
Controller display is in
wrong temperature
scale (Fahrenheit or
Celsius).
Incorrect display option
programmed.
Fryers using the 3000 controller can toggle
between F° to C° by pressing the
button until
Product setup is displayed. Press
to scroll to
Tech Mode and press
. Enter 1658. Press the
scan button. The controller displays
OFF
.
Turn the controller on to check temperature. If
the desired scale is not displayed, repeat. Fryers
using the CM3.5 should refer to the separate
Fryer Controllers User’s Manual.
Controller displays
High limit
failure
disconnect
power
or
HELP
.
A.
Open drain valve
B.
Failed high limit
A.
Close the drain valve.
B.
Shut the fryer down immediately and call
your FAS for assistance.
Controller displays
TEMP PROBE
FAILURE
or
PROB
.
Problem with the temperature
measuring circuitry including the
probe or damaged controller
wiring harness or connector.
Shut the fryer down and call your FAS for
assistance.
Controller displays
SERVICE
REQUIRED
followed
by an error message
.
An error has occurred which
requires a service technician.
Press the
(YES) button if the issue is fixed or
press the
(NO) button to continue cooking
and call your FAS for assistance. In some cases,
cooking may not be available.