2-9
5.
Check the programmed temperature thermostat setting. (Refer to chapter 4 3000
Computer
Instructions
) for the setpoint programming instructions for your particular controller.)
2.5 Converting to another Gas Type
DANGER
This appliance was configured at the factory for a specific type of gas. Converting from
one type of gas to another requires the installation of specific gas-conversion compo-
nents. Conversion instructions are included with conversion kits.
Switching to a different type of gas without installing the proper conversion
components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A
GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed
by qualified, licensed, and authorized installation or service personnel, as defined in
Section 1.7 of this manual.
OCF30
™
Series gas fryers manufactured for non-CE countries use different burners for each type gas.
The burners in fryers built for Propane gas have a special gray-colored coating on the burner tiles to
enable them to withstand the higher caloric value of the Propane gas. Burners designed for use in
propane units may be used in natural gas applications, but not vice versa.
Non-CE Gas Conversion Kits
Natural Gas to Propane (LP) Gas
Propane (LP) Gas to Natural Gas
Full Vat before 10/2010: PN 826-2527
Full Vat before 10/10: PN 826-2528
Dual Vat before 10/2010: PN 826-2529
Dual Vat before 10/10: PN 826-2530
Full Vat after 09/2010: PN 826-3278
Full Vat after 09/10: PN 826-2967
Dual Vat after 09/2010: PN 826-3279
Dual Vat after 09/10: PN 826-2968
Non-CE Gas Conversion Kits for Australia
Natural Gas to Propane (LP) Gas
Propane (LP) Gas to Natural Gas
Full Vat before 10/2010: PN 826-2745
Full Vat before 10/10: PN 826-2747
Dual Vat before 10/2010: PN 826-2746
Dual Vat before 10/10: PN 826-2748
Full Vat after 09/2010: PN 826-2969
Full Vat after 09/10: PN 826-2971
Dual Vat after 09/2010: PN 826-2970
Dual Vat after 09/10: PN 826-2972
Units manufactured for export to CE countries are equipped with “universal” burners that may be used
with either Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.
CE Gas Conversion Kits for Units with Gas Valve 810-1715
G20 or G25 (Natural) to G30 or G31 Gas:
G30 or G31 to G20 or G25 (Natural) Gas:
before 10/2010 PN 826-2973
before 10/10 PN 826-2974
after 09/2010 PN 826-3278
after 09/10 PN 826-2976