![Frymaster FPGL30 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/frymaster/fpgl30/fpgl30_installation-operation-and-maintenance-manual_2340501029.webp)
3-6
3.4.2 Routine Oil Changes
When the oil reservoir level is low, the controller displays
TOPOFF OIL EMPTY
in the left display
and
CONFIRM
in the right display. Press
(CONFIRM).
Some procedures may differ from photos
shown. Follow manufactures instructions for changing the JIB. If using solid shortening see Appendix B in
the rear of this manual for instructions.
1. Open the cabinet and slide the JIB from
the cabinet (see Figure 3).
Figure 3
2. Remove the cap and pour any remaining oil in the
container into all fry vats equally (see Figure 4).
Figure 4
3. With the jug upright remove the cap and
foil seal (see Figure 5).
Figure 5
4. Put the tube in the new full container (see Figure 6).
Figure 6
5. Slide the JIB onto the shelf inside the fryer cabinet
(as seen in Figure 3).
6. Press and hold the orange JIB reset switch
three (3)
seconds
to reset the top off system.
(see Figure 7).
3.4.3 Bulk Oil Systems
Instructions for installing and using bulk oil systems are found in Appendix C located
at the rear of this manual.
WARNING:
Do not add
HOT or USED oil to a JIB.
Figure 7
Image and location may differ