1-33
Problem
Probable Causes
Corrective Action
Controller displays
CHANGE FILTER
PAPER
.
Filter error has occurred, filter paper
clogged, 24 hour filter pad change prompt
has occurred or change filter paper was
ignored on a prior prompt.
Change the filter paper and ensure the filter pan
has been removed from the fryer for a minimum
of
30
seconds.
Do
NOT
ignore
CHANGE FILTER
PAPER
prompts.
Controller displays
INSERT pan
.
A.
Filter pan is not fully inserted into
fryer.
B.
Missing filter pan magnet.
C.
Defective filter pan switch.
A.
Pull filter pan out and fully reinsert into
fryer.
B.
Ensure the filter pan magnet is in place and
if missing replace.
C.
If the filter pan magnet is fully against the
switch and controller continues to display
INSERT pan
, switch is possibly
defective.
Controller displays
hot-hi-1
.
Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF
(202ºC).
This indicates that the vat temperature has
exceeded certain parameters and has
discontinued heating. It is also displayed
during a high limit test.
Controller displays
HI-
LIMIT.
Controller in high-limit test mode.
This is displayed only during a test of the high-
limit circuit and indicates that the high-limit has
opened properly.
Controller displays vat
temperature
alternating
with
MLT-
CYCL
.
Frypot temperature is below 180°F
(82°C).
This display is normal when the fryer is first
turned on while in the melt cycle mode. To
bypass the melt cycle press the “COOL”
button. The controller displays
EXIT
MELT?
alternating with
YES NO
. Press the
YES button to exit melt. If the display
continues, the fryer is not heating.
Controller displays
TEMP PROBE
FAILURE.
A.
Problem with the temperature
measuring circuitry including the
probe.
B.
Damaged controller wiring harness or
connector.
A.
This indicates a problem within the
temperature measuring circuitry. Check
resistance of probe, if faulty replace probe.
B.
Swap the controller wiring harness with
one known to be good. If problem is
corrected, replace the harness.
FILTER
and
CLEAN and
FILER
won’t start.
Temperature too low.
Ensure fryer is at setpoint before starting these
functions.
Controller displays
HEATING
FAILURE.
Failed controller, failed interface board,
open high-limit thermostat.
Turn off the vat with the issue. The error is
displayed if the fryer loses its ability to heat oil.
It is also displayed when the oil temperature is
above 450°F (232°C) and the high-limit
thermostat has opened, halting the heating of
the oil.
Controller will not go
into program mode or
some buttons do not
actuate.
Failed controller.
Replace controller
Controller displays
HI
2 BAD.
Controller in high-limit test mode.
This is displayed during a test of the high-limit
circuit to indicate if the high-limit has failed.
Controller displays
HELP HI-2
or
HIGH
LIMIT FAILURE
.
Failed high-limit.
This is displayed to indicate the high-limit has
failed.