3-4
Pressing the Boil Mode (
L
) switch overrides the programmed setpoint and the cookpot temperature
rises to boiling at 212
°
F (100
°
C). When the unit is in boil mode,
boiL
appears in both LED
displays. The unit remains in boil mode until the Simmer Mode switch is pressed or the unit is
turned off.
Pressing the Simmer Mode (
R
) switch causes the cookpot temperature to be maintained at the
programmed setpoint. If the cookpot temperature is above the setpoint,
°
-HI
is displayed in both
LED widows. If the cookpot temperature is below the setpoint,
°
-Lo
is displayed. Four dashes
(
- - - -
) are displayed if the temperature is within 11
°
F (6
°
C) of setpoint.
1
1
3
2
2
5
4
6
7
8
1 LED Displays
5 Boil Mode Switch
2 Power Switches
6 Product Buttons 1 through 5
3 Temperature Check/Program Lock
7 Product Buttons 6 through 10
4 Program Mode Switch
8 Simmer Mode Switch
P
ROGRAMMING THE
FBKR18 S
ERIES
C
OMPUTER
CAUTION
It is recommended that the simmer setpoint and the heat/stir times for
all 10
products be programmed before the unit is first used in a rethermalizing cycle
.
The simmer setpoint and product rethermalizing times are programmed at the factory. These are
test
settings
not
default settings. You must program the unit for your own particular products.
Program the setpoint and all product rethermalizing times as follows:
1. Turn the computer on by pressing the Power switch.
2. Enter the programming mode by pressing the Program Mode switch.
CodE
appears in the
left display. Press the switch again to exit the programming mode.