1-12
Remove these screws to
remove the shield from the
blower assembly.
Remove these nuts to
separate the blower
motor from the housing.
3.
Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or
detergent on the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse
the wheel and housing with hot tap water, then dry with a clean cloth.
Blower Housing
Blower Wheel
Wrap the motor and wires
with plastic wrap or a
plastic bag.
4.
Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor
assembly and blower housing. Reinstall the blower shield.
5.
Reinstall the blower assembly in the fryer and reconnect the wiring disconnected in Step 1.
6.
Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1.2 of the
BIPH52/55-MPH52/55 Series Gas Fryer Installation and Operation Manual (P/N 819-6087).
Содержание BIPH52 Series
Страница 28: ...1 21 Disassembling A Frypot Full Vat Illustrated Spacers Spacer 10 2 3 4 5 6 7 8 1 11 9 ...
Страница 46: ...1 39 1 11 2 Transformer Filter Boxes 1 11 2 1 MPH152 155 Transformer Filter Box ...
Страница 48: ...1 41 1 11 2 3 BIPH252 255 and 452 455 Transformer Filter Box International 8051340C ...
Страница 50: ...1 43 1 11 2 5 BIPH352 355 Transformer Filter Box International ...
Страница 66: ...2 13 2 4 2 Drain Valves and Associated Components ...
Страница 68: ...2 15 2 4 3 Rear Flush Oil Return Line Components ...
Страница 72: ...2 19 2 5 2 Transformer Boxes ...
Страница 76: ...2 23 2 7 Frypots and Associated Components 2 7 1 Full Vat Frypot Components ...
Страница 78: ...2 25 2 7 2 Dual Vat Frypot Components ...
Страница 86: ...2 33 Transformer Box Cable Assemblies 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 89: ...THIS PAGE INTENTIONALLY LEFT BLANK ...