1-4
FREQUENTLY USED TEST POINTS FOR INTERFACE BOARD 106-0386SP
Meter
Setting
12VAC Power to Controller
50VAC Scale
1 and 3 on J3 or J2
12-18
24VAC Power to Right Module
50VAC Scale
8 on J3 and GROUND
22-28
120 VAC Power
250VAC Scale
11 on J3 and GROUND
110-125
120 VAC Power to Blowers
250VAC Scale
12 on J3 and GROUND
110-125
24VAC Power to Full- or Right-vat High-Limit
50VAC Scale
9 on J3 and GROUND
22-28
24VAC Power to Left High-Limit (if present)
50VAC Scale
9 on J1 and GROUND
22-28
Probe Resistance (Full- or Right-vat) *
R x 1000 OHMS 2 and 6 on J3 or 13 and 14 on J2
**
Probe Resistance (Left - if present) *
R x 1000 OHMS 2 and 6 on J1 or 14 and 15 on J2
**
Probe Isolation
R x 1000 OHMS 6 on J1 or J3 and GROUND
***
High-Limit Continuity (Full- or Right-vat)
R x 1 OHM
9 on J3 and Wire 13C on Gas Valve
0
High-Limit Continuity (Left - if present)
R x 1 OHM
9 on J1 and Wire 12C on Gas Valve
0
** See Probe Resistance Chart at end of chapter.
*** 5 mega-Ohms or greater.
Test
Pins
Results
*
* Disconnect 15-pin harness from controller before testing probe circuit.
1.1.3 THERMOSTATS
BIPH52/55 and MPH52/55 Series gas fryers have
temperature probes
located on the front centerline
of each frypot (dual-vat frypots have two probes, one in each vat). In this type of thermostat, the
probe resistance varies directly with the temperature. That is, as the temperature rises, so does
resistance, at a rate of approximately 2 ohms for every 1º F. Circuitry in the controller monitors the
probe resistance and controls burner firing when the resistance exceeds or falls below programmed
temperatures (setpoints). The temperatures are programmed by means of a keypad on the face of the
controller.
BIPH52/55 and MPH52/55 Series fryers are also equipped with a
high-limit thermostat.
In the event
that the fryer fails to properly control the oil temperature, the high-limit thermostat prevents the fryer
from overheating to the flash point. The high-limit thermostat acts as a normally closed power
switch that opens when exposed to temperatures above 425ºF to 450ºF (218ºC to 232ºC). The
different types of thermostats have different part numbers for CE and Non-CE models, and are not
interchangeable.
1.2
Accessing Fryers for Servicing
DANGER
Moving a fryer filled with oil may cause spilling or splattering of the hot liquid.
Follow the draining instructions in Chapter 4 of the BIPH52/55-MPH52/55 Installation
and Operation manual (P/N 819-6087) before attempting to relocate a fryer for
servicing.
1.
Shut off the gas supply to the unit. Unplug the power cords. Disconnect the unit from the gas
supply.
Содержание BIPH52 Series
Страница 28: ...1 21 Disassembling A Frypot Full Vat Illustrated Spacers Spacer 10 2 3 4 5 6 7 8 1 11 9 ...
Страница 46: ...1 39 1 11 2 Transformer Filter Boxes 1 11 2 1 MPH152 155 Transformer Filter Box ...
Страница 48: ...1 41 1 11 2 3 BIPH252 255 and 452 455 Transformer Filter Box International 8051340C ...
Страница 50: ...1 43 1 11 2 5 BIPH352 355 Transformer Filter Box International ...
Страница 66: ...2 13 2 4 2 Drain Valves and Associated Components ...
Страница 68: ...2 15 2 4 3 Rear Flush Oil Return Line Components ...
Страница 72: ...2 19 2 5 2 Transformer Boxes ...
Страница 76: ...2 23 2 7 Frypots and Associated Components 2 7 1 Full Vat Frypot Components ...
Страница 78: ...2 25 2 7 2 Dual Vat Frypot Components ...
Страница 86: ...2 33 Transformer Box Cable Assemblies 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 89: ...THIS PAGE INTENTIONALLY LEFT BLANK ...