1-6
3.
Insert the fitting for a gas pressure-measuring device into the pressure tap hole.
4.
On non-CE fryers only
, place the gas valve in the ON position.
5.
Place the fryer power switch in the ON position. When the burner has lit and burned steadily for
at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table below. The tables list the burner manifold gas pressures for each of the gas
types that can be used with this equipment.
Gas
Single
Vat
Dual
Vat
Natural Gas Lacq
(G20) under 20 mbar
7
7
Natural Gas Gronique
*
(G25) under 25 mbar
10
10
Natural Gas Gronique
(G25) under 20 mbar
10
10
Butane/Propane
(G30) at 28/30 or 50 mbar
17
17
Propane
(G31) under 37 or 50 mbar
20
20
CE Standard
Burner Manifold Gas Pressures
Pressure (mbar)
* Belgian G25 = 7,0 mbar (single or dual)
Gas
Pressure
Natural
3" W.C.
0.73 kPa
Propane
8.25" W.C.
2.5 kPa
Non-CE Standard
Burner Manifold Gas Pressures
6.
To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust to the
correct pressure.
Non-CE
Valve
CE
Valve
GAS VALVE REGULATOR CAP
Содержание BIPH52 Series
Страница 28: ...1 21 Disassembling A Frypot Full Vat Illustrated Spacers Spacer 10 2 3 4 5 6 7 8 1 11 9 ...
Страница 46: ...1 39 1 11 2 Transformer Filter Boxes 1 11 2 1 MPH152 155 Transformer Filter Box ...
Страница 48: ...1 41 1 11 2 3 BIPH252 255 and 452 455 Transformer Filter Box International 8051340C ...
Страница 50: ...1 43 1 11 2 5 BIPH352 355 Transformer Filter Box International ...
Страница 66: ...2 13 2 4 2 Drain Valves and Associated Components ...
Страница 68: ...2 15 2 4 3 Rear Flush Oil Return Line Components ...
Страница 72: ...2 19 2 5 2 Transformer Boxes ...
Страница 76: ...2 23 2 7 Frypots and Associated Components 2 7 1 Full Vat Frypot Components ...
Страница 78: ...2 25 2 7 2 Dual Vat Frypot Components ...
Страница 86: ...2 33 Transformer Box Cable Assemblies 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 89: ...THIS PAGE INTENTIONALLY LEFT BLANK ...