![Fronius TransTig 1700 Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/fronius/transtig-1700/transtig-1700_operating-instructions-manual_2339442089.webp)
Troubleshooting
General
The digital power sources are equipped with an intelligent safety system. This
means that apart from the fuse for the coolant pump, it has been possible to dis-
pense with fuses entirely. After a possible malfunction or error has been
remedied, the power source can be put back into normal operation again without
any fuses having to be replaced.
Safety
WARNING!
Work that is carried out incorrectly may result in serious injury or damage to
property.
▶
All the work described below must only be carried out by trained and quali-
fied personnel.
▶
Do not carry out any of the work described below until you have fully read
and understood this document.
▶
Do not carry out any of the work described below until you have fully read
and understood all of the documents relating to the system components, in
particular the safety rules.
WARNING!
An electric shock can be fatal.
Before starting the work described below:
▶
Turn the power source mains switch to the "O" position
▶
Disconnect the power source from the grid
▶
Ensure that the power source remains disconnected from the mains until all
work has been completed
▶
After opening the device, use a suitable measuring instrument to check that
electrically charged components (e.g. capacitors) have been discharged.
WARNING!
An inadequate ground conductor connection can cause serious injury or dam-
age.
The housing screws provide a suitable ground conductor connection for earthing
the housing.
▶
The housing screws must never be replaced with different screws unless a re-
liable ground conductor connection is established.
Displayed ser-
vice codes
If any error message that is not described here appears on the displays, then the
fault can only be fixed by After-Sales Service. Make a note of the error message
shown in the display and of the serial number and configuration of the power
source, and contact our After-Sales Service team with a detailed description of
the error.
tP1 | xxx
Note: xxx stands for a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
89
EN
Содержание TransTig 1700
Страница 2: ......
Страница 19: ...General information 19...
Страница 20: ...20...
Страница 25: ...Control elements and connections 25...
Страница 26: ...26...
Страница 45: ...Installation and commissioning 45...
Страница 46: ...46...
Страница 55: ...Welding 55...
Страница 56: ...56...
Страница 72: ...72...
Страница 73: ...Setup settings 73...
Страница 74: ...74...
Страница 87: ...Troubleshooting and maintenance 87...
Страница 88: ...88...
Страница 96: ...96...
Страница 97: ...Appendix 97...
Страница 98: ...98...
Страница 124: ......