![Fronius TransTig 1700 Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/fronius/transtig-1700/transtig-1700_operating-instructions-manual_2339442102.webp)
Striking voltage (U
p
)
9.5 kV
The arc striking voltage is suitable for manual operation.
Degree of protection
IP 23
Type of cooling
AF
Insulation class
B
EMC device class
(in accordance with EN/IEC 60974-10)
A
Dimensions L/W/H (with handle)
485 / 180 / 390 m
m
19.1 / 7.1 / 15.4 in.
Weight (without handle)
17.4 kg
38.3 lb.
Weight (with handle)
17.8 kg
39.2 lb.
Mark of conformity
S, CE
Idle state power consumption at 230 V
32.3 W
Power source efficiency at 180 A / 27.2 V
81%
MagicWave 2500
Mains voltage
3 x 400 V
Mains voltage tolerance
± 15%
Grid frequency
50/60 Hz
Mains fuse protection (slow-blow)
16 A
Mains connection
1)
Z
max
on PCC
3)
= 122 mOhm
Primary continuous power (100% D.C.
2)
)
4.7 kVA
Cos phi
0.99
Welding current range
TIG
3 - 250 A
Electrode
10 - 250 A
Welding current at
10 min/40 °C (104 °F) 35% D.C.
2)
-
10 min/40 °C (104 °F) 40% D.C.
2)
250 A
10 min/40 °C (104 °F) 100% D.C.
2)
180 A
Open circuit voltage
89 V
Working voltage
TIG
10.1 - 20.0 V
Electrode
20.4 - 30.0 V
Striking voltage (U
p
)
10 kV
The arc striking voltage is suitable for manual operation.
Degree of protection
IP 23
102
Содержание TransTig 1700
Страница 2: ......
Страница 19: ...General information 19...
Страница 20: ...20...
Страница 25: ...Control elements and connections 25...
Страница 26: ...26...
Страница 45: ...Installation and commissioning 45...
Страница 46: ...46...
Страница 55: ...Welding 55...
Страница 56: ...56...
Страница 72: ...72...
Страница 73: ...Setup settings 73...
Страница 74: ...74...
Страница 87: ...Troubleshooting and maintenance 87...
Страница 88: ...88...
Страница 96: ...96...
Страница 97: ...Appendix 97...
Страница 98: ...98...
Страница 124: ......