“con” parameter (constant welding current)
-
If the “con” parameter is set, the welding current will be kept constant, irrespective of
the welding voltage. This results in a vertical characteristic (4).
-
The “con” parameter is especially suitable for rutile electrodes and basic electrodes,
as well as for arc air gouging.
-
For arc air gouging, set the arc-force dynamic to "100".
Parameter "0.1 - 20" (drooping characteristic with adjustable slope)
-
Parameter “0.1 - 20” is used to set a drooping characteristic (5). The setting range ex-
tends from 0.1 A / V (very steep) to 20 A / V (very flat).
-
Setting a flat characteristic (5) is only advisable for cellulose electrodes.
"P" parameter (constant welding power)
-
If the “P” parameter is set, the welding power is kept constant, irrespective of the weld-
ing voltage and welding current. This results in a hyperbolic characteristic (6).
-
The “P” parameter is particularly suitable for cellulose electrodes.
Starting curr time
Unit
s
Setting range
OFF / 0.01 - 9.9
The starting current time t-S specifies the duration of the starting-current phase I
s
.
Char
For selecting characteristics
Unit
Setting range
con or 0.1 - 20 or P
Factory setting
con
(1)
Load line for rod electrode
(2)
Load line for rod electrode where arc length is in-
creased
(3)
Load line for rod electrode where arc length is re-
duced
(4)
Characteristic where "CON" parameter is select-
ed (constant welding current)
(5)
Characteristic where "0.1 - 20" parameter is se-
lected (drooping characteristic with adjustable
slope)
(6)
Characteristic where "P" parameter is selected
(constant welding power)
(7)
Example of pre-set arc-force dynamic where
characteristic (4) is selected
(8)
Example of pre-set arc-force dynamic where
characteristic (5) or (6) is selected
Characteristics that can be selected using the characteristic function
NOTE!
When setting a flat characteristic (5), set the arc-force dynamic to a higher
value.
NOTE!
If there are problems with a rod electrode tending to "stick", set the arc-
force dynamic to a higher value.
0
0
4
0
200
100
300
I (A)
U (V)
con - 20 A / V
(4)
(5)
(6)
(7)
(8)
(1)
(2)
(3)
Содержание MagicWave 2200 Comfort
Страница 2: ...2...
Страница 4: ...4...
Страница 10: ...10...
Страница 23: ...General information...
Страница 24: ......
Страница 27: ...Control elements and connections...
Страница 28: ......
Страница 39: ...Installation and commissioning...
Страница 40: ......
Страница 45: ...Welding...
Страница 46: ......
Страница 89: ...Setup settings...
Страница 90: ......
Страница 170: ...170...
Страница 171: ...Troubleshooting and maintenance...
Страница 172: ......
Страница 183: ...183 EN Disposal Dispose of in accordance with the applicable national and local regulations...
Страница 184: ...184...
Страница 185: ...Appendix...
Страница 186: ......
Страница 195: ...Spare parts and circuit diagrams...
Страница 196: ...196 Spare parts list TransTig MagicWave 2200 Comfort...
Страница 197: ...197...
Страница 198: ...198 Spare parts list TransTig MagicWave 2500 3000...
Страница 200: ...200 Spare parts list TransTig 4000...
Страница 201: ...201...
Страница 202: ...202 Spare parts list MagicWave 4000...
Страница 203: ...203...
Страница 204: ...204...
Страница 205: ...205 Circuit diagrams MagicWave 2200 Comfort V 12 06 2014...
Страница 206: ...206 Circuit diagrams MagicWave 2500 Comfort...
Страница 207: ...207 Circuit diagrams MagicWave 3000 Comfort...
Страница 208: ...208 Circuit diagrams MagicWave 4000 Comfort V 17 12 2012 1 2...
Страница 209: ...209 V 17 12 2012 2 2...
Страница 210: ...210 Circuit diagrams TransTig 2200 Comfort V 14 12 2010...
Страница 211: ...211 Circuit diagrams TransTig 2500 Comfort...
Страница 212: ...212 Circuit diagrams TransTig 3000 Comfort...
Страница 213: ...213 Circuit diagrams TransTig 4000 Comfort V 17 12 2012...
Страница 214: ......
Страница 215: ......