115
EN
Legend:
(1).... Gas post-flow time at any given mo-
ment
(2).... Welding current at any given mo-
ment
G-H.... Post-flow lmax
G-L .... Post-flow lmin
Gas post-flow time as a function of the welding current
Gas qtity
Command value for protective gas shield flow (only with the "digital gas control" option)
Unit
l/min
cfh
Setting range
OFF / 5.0 - max.
OFF / 10.71 - max.
Factory setting
15
32.14
IMPORTANT!
Please refer to "Digital Gas Control" operating instructions for more de-
tailed explanations of the "gas flow rate" welding parameter.
Gas correction
(only with the “Digital Gas Control“ option)
Unit
-
Setting range
AUT / 1.0 - 10.0
Factory setting
AUT
IMPORTANT!
Please refer to "Digital Gas Control" operating instructions for more de-
tailed explanations of the "gas correction" welding parameter.
Gas flushing
Purging of protective gas shield
Unit
min
Setting range
OFF / 0.1 - 10.0
Factory setting
OFF
Purging of the protective gas shield begins as soon as "gas flushing" is allocated a value.
For safety reasons, purging of the shielding gas cannot be restarted until a new gas flush-
ing value is entered.
IMPORTANT!
Purging of the protective gas shield is necessary if condensation forms
when the device is left unused in a cold environment for a prolonged period. Long hose-
packs are most affected.
I
min
I
max
I
t
G-H
G-L
(1)
(2)
Содержание MagicWave 2200 Comfort
Страница 2: ...2...
Страница 4: ...4...
Страница 10: ...10...
Страница 23: ...General information...
Страница 24: ......
Страница 27: ...Control elements and connections...
Страница 28: ......
Страница 39: ...Installation and commissioning...
Страница 40: ......
Страница 45: ...Welding...
Страница 46: ......
Страница 89: ...Setup settings...
Страница 90: ......
Страница 170: ...170...
Страница 171: ...Troubleshooting and maintenance...
Страница 172: ......
Страница 183: ...183 EN Disposal Dispose of in accordance with the applicable national and local regulations...
Страница 184: ...184...
Страница 185: ...Appendix...
Страница 186: ......
Страница 195: ...Spare parts and circuit diagrams...
Страница 196: ...196 Spare parts list TransTig MagicWave 2200 Comfort...
Страница 197: ...197...
Страница 198: ...198 Spare parts list TransTig MagicWave 2500 3000...
Страница 200: ...200 Spare parts list TransTig 4000...
Страница 201: ...201...
Страница 202: ...202 Spare parts list MagicWave 4000...
Страница 203: ...203...
Страница 204: ...204...
Страница 205: ...205 Circuit diagrams MagicWave 2200 Comfort V 12 06 2014...
Страница 206: ...206 Circuit diagrams MagicWave 2500 Comfort...
Страница 207: ...207 Circuit diagrams MagicWave 3000 Comfort...
Страница 208: ...208 Circuit diagrams MagicWave 4000 Comfort V 17 12 2012 1 2...
Страница 209: ...209 V 17 12 2012 2 2...
Страница 210: ...210 Circuit diagrams TransTig 2200 Comfort V 14 12 2010...
Страница 211: ...211 Circuit diagrams TransTig 2500 Comfort...
Страница 212: ...212 Circuit diagrams TransTig 3000 Comfort...
Страница 213: ...213 Circuit diagrams TransTig 4000 Comfort V 17 12 2012...
Страница 214: ......
Страница 215: ......