101
EN
The special HF ignition indicator remains lit as long as a value has been specified
for the HF ignition parameter.
If the “HF ignition” set-up parameter is set to “OFF”, no high frequency ignition takes place
at the start of welding. In this case, welding starts with touchdown ignition.
rPI ignition
Reversed polarity ignition
Unit
-
Setting range
ON / OFF
Factory setting
OFF
IMPORTANT!
The rPI ignition function
-
is only available on the MagicWave power source
-
is not recommended for welding light-gauge sheets
L/R alignment
L (inductivity) - welding circuit inductivity (in microhenry)
R (resistance) - welding circuit resistance (in mOhm)
See the "L/R alignment" section for further details.
Ignition time-out
Time until safety cut-out is triggered after abortive ignition attempt
Unit
s
Setting range
0,1 - 9,9
Factory setting
5
IMPORTANT!
"Ignition Time-Out" is a safety function so it cannot be deactivated. A de-
scription of the ignition time out function may be found in the Chapter "TIG welding".
Arc break
Arc break watchdog
Time until safety cut-out following an arc break
Unit
s
Setting range
0,1 - 9,9
Factory setting
2
IMPORTANT!
The arc break watchdog is a safety function and cannot be deactivated. A
description of the arc break watchdog function may be found in the section "TIG welding".
Содержание MagicWave 2200 Comfort
Страница 2: ...2...
Страница 4: ...4...
Страница 10: ...10...
Страница 23: ...General information...
Страница 24: ......
Страница 27: ...Control elements and connections...
Страница 28: ......
Страница 39: ...Installation and commissioning...
Страница 40: ......
Страница 45: ...Welding...
Страница 46: ......
Страница 89: ...Setup settings...
Страница 90: ......
Страница 170: ...170...
Страница 171: ...Troubleshooting and maintenance...
Страница 172: ......
Страница 183: ...183 EN Disposal Dispose of in accordance with the applicable national and local regulations...
Страница 184: ...184...
Страница 185: ...Appendix...
Страница 186: ......
Страница 195: ...Spare parts and circuit diagrams...
Страница 196: ...196 Spare parts list TransTig MagicWave 2200 Comfort...
Страница 197: ...197...
Страница 198: ...198 Spare parts list TransTig MagicWave 2500 3000...
Страница 200: ...200 Spare parts list TransTig 4000...
Страница 201: ...201...
Страница 202: ...202 Spare parts list MagicWave 4000...
Страница 203: ...203...
Страница 204: ...204...
Страница 205: ...205 Circuit diagrams MagicWave 2200 Comfort V 12 06 2014...
Страница 206: ...206 Circuit diagrams MagicWave 2500 Comfort...
Страница 207: ...207 Circuit diagrams MagicWave 3000 Comfort...
Страница 208: ...208 Circuit diagrams MagicWave 4000 Comfort V 17 12 2012 1 2...
Страница 209: ...209 V 17 12 2012 2 2...
Страница 210: ...210 Circuit diagrams TransTig 2200 Comfort V 14 12 2010...
Страница 211: ...211 Circuit diagrams TransTig 2500 Comfort...
Страница 212: ...212 Circuit diagrams TransTig 3000 Comfort...
Страница 213: ...213 Circuit diagrams TransTig 4000 Comfort V 17 12 2012...
Страница 214: ......
Страница 215: ......