28
Settings on the "Remote Control" dip switches
The "Remote Control" dip switches are used to select the power source remote control
whose functionality needs to be simulated for the robot or machine controller. The param-
eters for the following remote controls can be simulated:
-
TR 55 r
-
TR 50 mc
-
TP mc
"Puls Synch TIG" and "Start Robot" setting:
-
Dip switch for "Puls Synch TIG" to "on"
-
Dip switch for "Start Robot" to "on"
"Puls Robot":
The signal for pulsing the cold wire is set by the robot or machine controller.
-
The wire speed switches between 0 and the entered set value, according to the sig-
nal for pulsing.
"Puls Synch TIG":
Pulsing of the cold wire is set by the power source.
-
The wire speed switches between 0 and the entered set value, synchronous with
pulsing of the welding current.
"Start Robot":
Wirefeeding is initiated by the robot controller.
-
Irrespective of the operating status of the power source
"Start TIG":
Wirefeeding begins when the welding current has reached the main current phase.
-
The main current phase is between the start current and final current phase
NOTE!
Only use the dip switch settings appropriate for "Remote Control".