11
3
2
3
1
4
5
4
2
1
Closing inverter and finishing mounting
Connecting
Inverter / Starting
up Load
(continued)
NOTE
Improperly connected battery cables can cause damage. Secure the
battery’s negative terminal with a 200 A direct current fuse. The battery cable
being used must correspond to the given lengths and
min. diameters.
5
2
1
200A
Connecting inverter to battery (single operation)
min. Ah
max. L
A
min.
200 A
Min. requirement
Inverter
max. L
A
min.
min. Ah
IS 15
2 m (6.56 ft.)
25 mm
2
(.039 in
2
)
300 Ah
IS 15 - 48 V
3 m (9.84 ft.)
25 mm
2
(.039 in
2
)
150 Ah
IS 30
1.5 m (4.9 ft.)
35 mm
2
(.054 in
2
)
500 Ah
IS 30 - 48 V
2 m (6.56 ft.)
25 mm
2
(.039 in
2
)
300 Ah
Recommended configuration
Inverter
max. L
A
min.
min. Ah
IS 15
2 m (6.56 ft.)
35 mm
2
(.054 in
2
)
500 Ah
IS 15 - 48 V
3 m (9.84 ft.)
35 mm
2
(.054 in
2
)
250 Ah
IS 30
1.5 m (4.9 ft.)
50 mm
2
(.077 in
2
)
1000 Ah
IS 30 - 48 V
2 m (6.56 ft.)
35 mm
2
(.054 in
2
)
500 Ah