46
Software version
The full version number of the currently installed software is spread across a number of
displays and can be retrieved by turning the adjusting dial.
Automatic switch-off (time Shut down)
300 - 9000 Seconds / OFF
If the power source is not operated for the specified length of time, it switches off automat
-
ically.
Factory setting: 900 seconds
Factory setting (FACtory)
no / YES / ALL
The power source can be reset to its factory settings here.
-
Cancel reset
-
Reset the parameters for the selected welding process to their factory settings
-
Reset the parameters for all welding processes to their factory settings
Resetting of the selected value to its factory setting must be confirmed by pressing
the adjusting dial.