Test mode
General
Do not connect the charger to the grid during testing. In all tests, the charger draws its
supply from the battery being tested.
WARNING!
Danger due to exposed, rotating vehicle parts.
This can result in serious injury and damage to property.
▶
When working in the vehicle's engine compartment, take care that hands, hair, items
of clothing and charging leads do not come into contact with moving parts, e.g. fan
belt, fan, etc.
Once the charger has been connected to the battery, the following test phases run auto-
matically in sequence:
-
Testing the battery open circuit voltage
-
Battery starting capability test (only on chargers for motor vehicle applications)
-
Generator test (only on chargers for motor vehicle applications)
Please note:
All battery and alternator test results are for information only and may differ from the
actual values.
The charger checks the entire system. The results are therefore to be taken as recom-
mendations only.
Testing the bat-
tery open circuit
voltage
The charger measures the open circuit voltage of the battery. If the battery was not used
for at least two hours, then this is referred to as open circuit voltage.
1
Switch off engine and ignition, shed all loads
2
Establish connection to battery
3
All display elements on the display are activated. Depending on the type of charger,
the respective voltage(s) and/or symbol for the type of battery are displayed.
4
Charger measures battery open circuit voltage
5
Charger displays battery open circuit voltage for 15 seconds
Battery ready for use
Charge battery
100%
80%
50%
20%
0%
Testing battery
startability (Acc-
tiva Easy char-
gers only)
6
After the open circuit voltage test, the charger switches automatically to the startabi-
lity test and awaits the start process
32
Содержание Acctiva Easy 12/24
Страница 2: ......
Страница 3: ...3...
Страница 22: ...22...
Страница 40: ...The proper functioning of the charger is tested at 5 85 humidity climate class B 40...
Страница 41: ...41...
Страница 61: ...61...
Страница 80: ...80...
Страница 98: ...Cihaz n fonksiyonu 5 85 oran nda hava neminde test edilmi tir par as zelli i klim s n f B 98...
Страница 99: ...99 TR...