16
Wiring terminals
for inputs and
outputs
Fig. 10 Connecting cables for inputs and outputs
-
Maximum cable cross-section: 2.5 mm² (0.00388 in.²)
-
Recommended tightening torque for terminal screws (1): 0.6 Nm
1. Insert the cable ends with ferrules into the terminals of the 9-pin plugs X3 and X4
2. Secure cables using terminal screws (1)
3. Plug the 9-pin plugs into 9-pin bases
X3 - Sensor supply
Pin
Description
-
I
max
1
+ 24 V
-
315 mA
2
GND
-
-
X3 - Tank valve 1
Pin
Description
U
25 F / 50 F
I
max
3
Tank valve 1: contact 13 20 - 30 V / 45 - 60 V
2 A / 0.4 A
4
Tank valve 1: contact 14 20 - 30 V / 45 - 60 V
2 A / 0.4 A
X3 - Tank valve 2
Pin
Description
U
25 F / 50 F
I
max
5
Tank valve 2: contact 13 20 - 30 V / 45 - 60 V
2 A / 0.4 A
6
Tank valve 2: contact 14 20 - 30 V / 45 - 60 V
2 A / 0.4 A
X3 - Relay
Pin
Description
U
25 F / 50 F
I
max
7
Relay: contact 13
20 - 30 V / 45 - 60 V
2 A / 0.4 A
8
Relay: contact 14
20 - 30 V / 45 - 60 V
2 A / 0.4 A
9-pin base X3
(1)
0.6 Nm
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
1
2 2 2 2 2 2 2 2 2
3
9-pin plug X3
(1)
0.6 Nm
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
1
2 2 2 2 2 2 2 2 2
3
9-pin base X4
9-pin plug X4