4 | Technical information
24
M2250322_en | Installation instructions Wood chip boiler T4e 200-350
Description
T4e 200 – 250 ESP
200
230
250
Auxiliary current consumption at rated heat output
(el
max
)
kW
0.218
0.251
0.272
Auxiliary current consumption at 30% of rated heat
output (η
p
)
0.092
0.092
0.092
Auxiliary current consumption in standby mode (P
SB
)
0.029
0.029
0.029
Regulation (EU) 2015/1189 – emissions in [mg/m³]
1)
Annual space heating emissions of dust (PM)
≤ 30
Annual space heating emissions of gaseous organic compounds
(GOC)
≤ 20
Annual space heating emissions of carbon monoxide (CO)
≤ 380
Annual space heating emissions of nitrogen oxides (NO
x
)
≤ 200
1. The emissions of dust, gaseous organic compounds, carbon monoxide and nitrogen oxides are stated in a standardised form based on dry flue gas with a oxygen content of 10 % and
under standard conditions at 0°C and 1013 millibar