Installation | 5
M2050222_en | Installation instructions Lambdamat LM 1500 KOM
19
5.3.1 Fit the ash duct for ash removal of the combustion chamber (only with
Lambdamat 750).
NOTICE! If ash is to be removed from the boiler via an ash screw, a base must be
provided by the customer beneath the boiler.
If an ash screw (optional) is provided for removing ash from the combustion chamber, the
ash duct should be fitted as follows when the combustion chamber is being positioned.
r
Fit the ash duct to the underside of the combustion chamber.
5.3.2 Bolting together the combustion chamber and heat exchanger
r
Position the heat exchanger on the centre of the combustion chamber and secure to
the combustion chamber with 4x screws and nuts.
Ä
Also screw on the earthing wire (supplied) with the toothed washer as potential
equalisation.