![Frog Pool Frog Twin Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/frog/pool-frog-twin/pool-frog-twin_instruction-manual_2338614005.webp)
5
Fire, explosion and high pressure hazards
To minimize the risk of serious injury, death or property damage while using the POOL FROG Twin Cyclers:
a
Read, understand and follow all instructions and safety precautions in the manual, and on these POOL FROG Twin Cyclers and on any
label for chemicals used with these Cyclers including POOL FROG Pacs, POOL FROG Mineral Reservoir and FROG BAM Algae Preventative.
DANGER
a
Never use fast dissolving chlorine tablets, liquid bleach, or calcium hypochlorite in the POOL FROG Twin Cyclers.
a
Never mix Trichlor chlorine tablets with Calcium Hypochlorite, or with any other form of concentrated chlorine or other chemicals.
a
Never add any other types of chlorine, pH adjusters, shock treatments or algaecides through the skimmer.
These products should be added directly into the pool if required.
a
Do not contaminate the POOL FROG Twin Cyclers, POOL FROG Mineral Reservoir, POOL FROG Pac or FROG BAM with dirt,
organic matter, pool chemicals (such as calcium hypochlorite or pool shocks), fertilizers or other household chemicals. Contact
between any of these substances and the POOL FROG Twin Cyclers, POOL FROG Mineral Reservoir, POOL FROG Pac or FROG
BAM, will result in a chemical reaction with the generation of heat, liberation of hazardous gasses and fire or explosion.
WARNING
a
Use only POOL FROG Pacs, POOL FROG Mineral Reservoir, and FROG BAM in the POOL FROG Twin Cyclers. Never use bulk chemicals.
a
To prevent the build up of gas pressure in the POOL FROG Twin Cyclers, be sure the pool return line valves are open –
except when opening or servicing the unit.
a
Do not inhale fumes from the POOL FROG Twin Cyclers or POOL FROG Pac.
a
Avoid sparks, smoking, or any open flame near POOL FROG Twin Cyclers or chemicals.
a
Do not exceed maximum operating pressure of 50 psi or maximum temperature of 104º F.
a
Do not remove the cap while under pressure. Always turn off pump and bleed off pressure before opening POOL FROG Twin Cyclers.
a
Do not install automatic or fast shut off valves downstream of POOL FROG Twin Cyclers.
a
Always install the POOL FROG Twin Cyclers AFTER a heater (if applicable) on the return line.
a
Always install any additional sanitizing equipment AFTER and NEVER BEFORE the POOL FROG Twin Cyclers are installed on the return line.
a
Do not permit children to use or climb on this product. This product must be positioned to prevent children from using it as a
means of access to the pool.
a
Always stand clear of the POOL FROG Twin Cyclers during pump start-up.
a
Replace POOL FROG Twin Cyclers if you see signs of cracks, damage or degradation to the Cycler bodies or caps.
NOTICE
a
Prior to pressurizing, check with your dealer to ensure your plumbing connections meet building codes.
a
Failure to properly winterize your POOL FROG Twin Cyclers could result in freeze damage. (See page 18 for winterizing details.)
Review this label before installing or operating this Cyclers. Contact King Technology at 800-222-0169 if this label is missing from your POOL
FROG Twin Cyclers.
Safety Label on POOL FROG Twin Cyclers