7
TOOLS NEEDED
Screwdriver
Pipe Wrench
INCLUDED WITH FROG
Pool Tender Cycler
Pipe Thread Tape
or Sealant
One 6” X 1½” TBE PVC
Nipple
MATERIALS NEEDED
One Hose Adapter
1½” X 1½” X 1¼”
One Section of
1½” or 1¼” Flex Hose
One
Hose Clamp
RECOMMENDED
4-8 psi Back Pressure
To avoid over or under chlorination,
replace eyeball fi ttings in the
return jets to a smaller or larger
size to adjust back pressure. For
best results use King Technology’s
pressure gauge, order Part No.
01-22-4000.
Sand Filter Installation with Nipple Kit and Flex Hose
Apply pipe
thread tape
or sealant
to each
threaded
end of
nipple.
1.
Screw either side of FROG
Pool Tender Cycler on to open
nipple end until upright and
secure.
Apply pipe thread tape or
sealant to threaded end of
hose adapter.
3.
4.
Screw adapter into the other side of FROG Pool Tender
Cycler. Hand tighten. Finish tightening by turning 1
to 2 revolutions with a pipe wrench.
DO NOT OVER
TIGHTEN
.
7.
To prevent damage to heaters or fi lters, see your
dealer about installing a
corrosion resistant
check valve
which will reduce the back fl ow of
chlorine gas when the FROG Pool Tender Cycler is
turned off.
Install
Screw one end of nipple into
the fi lter return. Hand tighten.
Finish tightening by turning
1 to 2 revolutions with a
pipe wrench.
DO NOT OVER
TIGHTEN.
2.
6.
5.
Attach return section of hose to the adapter with