background image

AMERBRITE

 White LED Pool Lamp Installation and User’s Guide

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

INSTALLATION

AND

USER’S GUIDE

AMERBRITE
UNDERWATER WHITE LED POOL LAMP

FOR USE ONLY WITH PENTAIR

 

  AMERLITE   LUMINAIRE

®

®

Содержание AMERBRITE

Страница 1: ...nstallation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY...

Страница 2: ...amps Using a Wall Switch 1 Operating AmerBrite White LED Lamps Using Control System 1 Using an External Transformer for Multiple AmerBrite 12 VAC Lamps 1 Maximum Wattage using Multiple AmerBrite White...

Страница 3: ...lectric shock When installing and using this electrical equipment basic safety precautions should always be followed include the following RISK OF ELECTRICAL SHOCK OR ELECTROCUTION This underwater lig...

Страница 4: ...restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the light without the test button being pushed a ground current is present indicating the pos...

Страница 5: ...mer for Multiple 12 VAC AmerBrite Lamps When using a 300 Watt UL Listed transformer set at 14 VAC with multiple 12 VAC AmerBrite lamps it is recommended that no more than four 4 AmerBrite lamps be use...

Страница 6: ...Box or for 12 volt models the low voltage transformer is located at least eight 8 inches 20 3 cm above water level and at least 48 inches 1 22 m from the edge of the pool See Figure 1 below The light...

Страница 7: ...l hazard resulting in death or serious injury to pool users installers or others due to electrical shock or b breakage of the lamp or lens which could result in serious injury to pool users installers...

Страница 8: ...the light assembly from the niche by tilting the top away from the niche and then lifting the light assembly from the locking tab at the bottom of the niche 4 Place the light assembly on the pool deck...

Страница 9: ...ainless Steel Light housing Be sure the LED assembly is level with the lamp housing CAUTION If the LED assembly is not level the LED assembly may interfere with the lens installation and or have impro...

Страница 10: ...Rotate the face ring so the pilot screw hole is aligned in the 12 O clock position with the lens letter N or W Note Also verify the TOP position arrow indicator label see page 7 on the rear of the ho...

Страница 11: ...t 45 22 Tighten the bolt and nut until the distance between the ends of the clamp equals inch or less 23 Install the special bronze pilot screw at the top of face ring to secure the light to the niche...

Страница 12: ...ction the width of the pool For lights located either end of the pool rotate the lens to the narrow N angle light beam position for increased underwater light intensity and distance WIDE ANGLE LIGHT B...

Страница 13: ...de 9 AmerBrite White LED Pool Lamp Illustrated Replacement Parts View Note A 120 VAC to 12 VAC external transformer is required for the 12 VAC model AmerBrite white pool lamp See page 1 for more infor...

Страница 14: ...ent 620065Z Kit Disc Assy AmerBrite White 120 12V 500W equivalent 8 620060Z Kit stem transformer assembly 120 VAC AmerBrite 9 620061Z Kit stem harness assembly 12 VAC AmerBrite 10 602070 AmerBrite Lam...

Страница 15: ...AMERBRITE White LED Pool Lamp Installation and User s Guide 11 NOTES...

Страница 16: ...d States and or other countries Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of...

Отзывы: