IMPORTANT:
Over chlorination or damage to the
FROG Pool Tender Cycler or other equipment could
result if special installations A, B or C are not used in
these situations.
Installation Tips to Ensure Proper Performance
1) If using a multi-speed pump, run
pump for at least 6 hours per day at
high speed (at least 40 gpm).
If the pump will run on low speed 24
hours per day or less than 6 hours per
day on high speed, you must bleed the
air while the pump is on by unscrewing
the back knob until water appears.
Then screw the knob back in. Repeat
this process each time the cap is
removed for any reason.
2) Install Cycler with 4-8 psi back pressure.
Lower back pressures could result in under
chlorination. Change the eyeball fi ttings in
the return jets to a smaller size to increase
back pressure. Contact King Technology at
800-222-0169 for a specially designed
Cycler pressure gauge to determine back
pressure at pool start-up.
3) Special installation Requirements:
A. With High Flow Rate
(greater than 80 gpm)
Install T-fi ttings exactly as shown.
B. With In-Floor Cleaner - TWO OPTIONS
The best option is to have two lines.
One line with pump, fi lter, heater and
FROG Pool Tender Cycler and a second line with a separate pump for the
in-fl oor cleaning system (fi lter optional).
OPTION 1- A Two-Line Installation
POOL RETURN
POOL WATER LEVEL
POOL WATER LEVEL
FROG Pool Tender Cycler
FROG Pool Tender
Cycler
IN-FLOOR
CLEANER
VALVE
FILTER
FILTER
HEATER
OPTION 2 - A 3-Way Valve Installation
POOL WATER LEVEL
3-way manual valve or 3-way motor valve plus controls
FROG Pool Tender
Cycler
IN-FLOOR
CLEANER
VALVE
FILTER
PUMP
PUMP
PUMP
C. Pool and Spillover Spa Combination
FROG Pool
Tender Cycler
Line 1
Line 2
•
If water fl ow is higher than 80 gallons per minute (gpm),
see diagram A.
•
If an in-fl oor cleaner is included with pool,
see
diagram B, with two options. Preferred
installation is Option 1 with two separate lines.
•
If set-up is a pool and spa combination with
common equipment, see diagram C.
Questions?
Call Customer Service at 800-222-0169
Monday thru Friday, 8 am to 5 pm central time.
WARNING
• Do not exceed maximum operating pressure of 50 psi.
• Do not install automatic or fast shut off valves
downstream of FROG Pool Tender Cycler.
• Always install the FROG Pool Tender Cycler AFTER the
heater (if applicable) on the return line.
• Always install any additional sanitizing equipment
AFTER and NEVER BEFORE the FROG Pool Tender
Cycler is installed on the return line.
Before installing, read all directions carefully and contact your dealer for installation support.
Part No. 01-22-4000